MIAMI, FL —
OSHA Inspection: CORE RESTORATION LLC
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of CORE RESTORATION LLC in 8300 SW 8TH STREET, MIAMI, FL 33144 (NAICS 236220). OSHA activity number 347679961.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- CORE RESTORATION LLC
- Site address
- 8300 SW 8TH STREET
- City
- MIAMI
- State
- FL
- ZIP
- 33144
- Mailing
- 2951 SOUTHWEST 72ND AVENUE, MIAMI, FL 33155
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236220
- Employees
- 7
- Ownership type
- A
Citations
5 citations on file for this inspection.
1926.451 B01
- Issued
- Feb 5, 2025
- Penalty
- Initial $9,931 · Current $5,959 Reduced
General-duty citation text
29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii) a) On or about August 12, 2024, located at, 8300 SW 8th Street, Miami FL. 33144, the employer did not ensure the scaffold was fully planked, exposing employees to a 7-feet 11-inch fall hazard while employees applying stucco cement to the exterior of a 4-story building.
Recent events (2)
- — I (S) $5958.6
- — Z (S) $9931
1926.451 E01
- Issued
- Feb 5, 2025
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairway's/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used. Cross braces were used as a means of access. a) On or about August 12, 2024, located at, 8300 SW 8th Street Miami FL 33144, the employer did not provide employees with a portable ladder, hook on ladder, attachable ladder stair tower, stairway type ladder, or a ramp to access the scaffold, thereby exposing employees to a 7-feet 11-inch fall hazard while observed climbing the sides of the scaffolding and cross braces to access the upper levels of the 40-foot scaffolding they were using to apply stucco cement to the sides of the exterior building.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.451 H02 II
- Issued
- Feb 5, 2025
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(h)(2)(ii): A toeboard was not erected along the edge of platforms more than 10 feet (3.1 m) above lower levels for a distance sufficient to protect employees below. a) On or about August 12, 2024, located at, 8300 SW 8th Street Miami FL 33144, the employer did not ensure workers working below the scaffolding were protected from being struck by falling tools by installing toeboards to the scaffolding while employees using hand tools to apply stucco to the sides of the building 30-feet above while other workers were working below the scaffolding.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.451 G01
- Issued
- Feb 5, 2025
- Penalty
- Initial $9,931 · Current $5,959 Reduced
General-duty citation text
29 CFR 1926.451(g)(1): Each employee on a scaffold more than 10 feet above a lower level was not protected from falling to that lower level. a) On or about August 12, 2024, located at, 8300 SW 8th Street, Miami FL 33144, the employer did not ensure fall protection was used for employees who were exposed to 30-feet fall hazard while they were working on a scaffold applying stucco cement without any means of fall protection.
Recent events (2)
- — I (S) $5958.6
- — Z (S) $9931
1926.451 G04
- Issued
- Feb 5, 2025
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(g)(4): Guardrail systems installed to meet the requirements of this section did not comply with the provisions listed in subparagraphs (i) through (xv) of this paragraph. a) On or about August 12, 2024, located at, 8300 SW 8th Street Miami FL 33144, the employer did not install a guardrail system to protect employees from falling while they were working on a 40-feet-high scaffold applying stucco to the sides of the building.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections in this industry (NAICS 236220)