Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: OMTEC CORPORATION

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of OMTEC CORPORATION in 181 LIBERTY STREET, MARLBOROUGH, MA 01752 (NAICS 333922). OSHA activity number 347680613.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Omtec Corporation — free Get an email when a new federal OSHA severe-injury report for Omtec Corporation is published. One employer, no account, unsubscribe in one click.
Establishment
OMTEC CORPORATION
Site address
181 LIBERTY STREET
City
MARLBOROUGH
State
MA
ZIP
01752
Mailing
181 LIBERTY STREET, MARLBOROUGH, MA 01752
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Last modified
Data loaded
NAICS code
333922
Employees
3
Ownership type
A

14 citations on file for this inspection.

1903.19 D01

Other-than-serious 1 instance 3 exposed
Issued
Jul 14, 2025
Abate by
Jul 31, 2025
Penalty
Initial $398 · Current $398
29 CFR 1903.19(d)(1) - The employer did not submit to the Agency documents demonstrating that abatement is complete for each willful or repeat violation and for any serious violation for which the Agency indicates in the citation that such abatement documentation is required:  Location - Throughout Facility  On or about 07/11/2025, the employer did not provide corrective action documentation for hazardous conditions specified in Citations 1-2, 1-3, 1-4, 1-6 and 1-7a through 1-7g as required.
Recent events (1)
  • — Z (O) $398

1910.22 A01

Serious Gravity 5 1 instance 2 exposed
Issued
Jan 31, 2025
Abate by
Feb 20, 2025
Penalty
Initial $2,837 · Current $2,837
CFR 1910.22(a)(1) - The employer did not ensure that all places of employment, passageways, storerooms, service rooms, and walking-working surfaces are kept in a clean, orderly, and sanitary condition:  Location - Heavy Machining Room  On or about 08/12/2024, employees were exposed to slip and fall hazards from power cords running along a walkway.
Recent events (1)
  • — Z (S) $2837

1910.37 B02

Serious Gravity 5 1 instance 4 exposed
Issued
Jan 31, 2025
Abate by
Feb 20, 2025
Penalty
Initial $3,547 · Current $3,547
29 CFR 1910.37(b)(2): Each exit was not clearly visible and marked by a sign reading "Exit":  Location - Carpentry Shop  On or about 08/12/2024, an exit route door leading from the facility to the exterior/front of the building, was not marked as an exit.
Recent events (1)
  • — Z (S) $3547

1910.147 C01

Serious Gravity 5 1 instance 2 exposed
Issued
Jan 31, 2025
Abate by
Mar 20, 2025
Penalty
Initial $3,547 · Current $3,547
29 CFR 1910.147(c)(1) - The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative:   Location - Throughout Facility  On or about 08/12/2024, the employer did not have a program to control hazardous energy to protect employees performing service and/or maintenance of equipment.
Recent events (1)
  • — Z (S) $3547

1910.178 L01 I

Serious Gravity 5 1 instance 4 exposed
Issued
Jan 31, 2025
Abate by
Mar 20, 2025
Penalty
Initial $3,547 · Current $3,547
29 CFR 1910.178(l)(1)(i) - The employer did not ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l):  Location - Throughout Facility  On or about 08/12/2024, employees had not been trained, evaluated, and/or certified to operate the powered industrial truck (PIT) as required.
Recent events (1)
  • — Z (S) $3547

1910.215 B09

Serious Gravity 5 1 instance 2 exposed
Issued
Jan 31, 2025
Abate by
Feb 20, 2025
Penalty
Initial $2,837 · Current $2,837
29 CFR 1910.215(b)(9) - The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch:  Location - Heavy Machining Room  On or about 08/12/2024, a workbench-mounted abrasive grinding wheel had the tongue guard adjusted in excess of 1/4 inch.
Recent events (1)
  • — Z (S) $2837

1910.255 B01

Serious Gravity 10 1 instance 4 exposed
Issued
Jan 31, 2025
Abate by
Mar 20, 2025
Penalty
Initial $4,965 · Current $4,965
29 CFR 1910.255(b)(1) - All external welding initiating control circuits were not operated on low voltage, not over 120 volts for the safety of the operators:  Location - Front Office Production Area  On or about 08/12/2024, employees were exposed to electrical hazards from high charge capacitors and other live wires on a Fusion Welding Machine.
Recent events (1)
  • — Z (S) $4965

1910.303 B08 I

Serious Gravity 10 1 instance 4 exposed
Issued
Jan 31, 2025
Abate by
Mar 20, 2025
Penalty
Initial $4,965 · Current $4,965
29 CFR 1910.303(b)(8)(i) - Electric equipment was not firmly secured to the surface on which it was mounted:  Location - Heavy Machining Room  On or about 08/12/2024, a junction box was not securely mounted as required.
Recent events (1)
  • — Z (S) $4965

1910.303 E01 II

Serious Gravity 5 1 instance 4 exposed
Issued
Jan 31, 2025
Abate by
Mar 20, 2025
Penalty
Initial $0 · Current $0
29 CFR 1910.303(e)(1)(ii) - Markings were not provided on electrical equipment for voltage, current, wattage and other ratings as necessary:  Location -  Throughout Facility  On or about 08/12/2024, employees were exposed electrical hazards when each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, was not legibly marked.
Recent events (1)
  • — Z (S) $0

1910.303 F02

Serious Gravity 5 1 instance 4 exposed
Issued
Jan 31, 2025
Abate by
Mar 20, 2025
Penalty
Initial $0 · Current $0
29 CFR 1910.303(f)(2) - Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, was not legibly marked to indicate its purpose, nor located and arranged so the purpose was evident:  Location -  Throughout Facility  On or about 08/12/2024, employees were exposed electrical hazards when each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, was not legibly marked.
Recent events (1)
  • — Z (S) $0

1910.303 G01

Serious Gravity 5 1 instance 4 exposed
Issued
Jan 31, 2025
Abate by
Mar 20, 2025
Penalty
Initial $0 · Current $0
29 CFR 1910.303(g)(1) - Sufficient access and working space was not provided and maintained about all electric equipment (operating at 600 volts, nominal, or less to ground) to permit ready and safe operation and maintenance of such equipment:  Location - Throughout Facility  On or about 08/12/2024, energized electrical breaker boxes were obstructed by various pieces of equipment.
Recent events (1)
  • — Z (S) $0

1910.305 B01 II

Serious Gravity 5 1 instance 4 exposed
Issued
Jan 31, 2025
Abate by
Mar 20, 2025
Penalty
Initial $0 · Current $0
29 CFR 1910.305(b)(1)(ii) - Unused openings in boxes, cabinets, or fittings were not effectively closed:  Location - Throughout Facility  On or about 08/12/2024, employees were exposed to electrical hazards from unused openings in various electrical fixtures.
Recent events (1)
  • — Z (S) $0

1910.305 B02

Serious Gravity 5 1 instance 4 exposed
Issued
Jan 31, 2025
Abate by
Mar 20, 2025
Penalty
Initial $0 · Current $0
29 CFR 1910.305(b)(2) - Pull boxes, junction boxes, and fittings were not provided with covers approved for the purpose:  Location - Heavy Machining Room  On or about 08/12/2024, employees were exposed to electrical hazards from uncovered electrical fixtures.
Recent events (1)
  • — Z (S) $0

1910.305 G01 IV A

Serious Gravity 5 1 instance 4 exposed
Issued
Jan 31, 2025
Abate by
Mar 20, 2025
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(1)(iv)(A) - Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure:  Location - Heavy Machining Room  On or about 08/12/2024, an extension cord connected to a grinder was plugged in and in use in place of permanent wiring.
Recent events (1)
  • — Z (S) $0

View Omtec Corporation's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347680613.