Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: PRIME METAL BUILDINGS & COMPONENTS

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of PRIME METAL BUILDINGS & COMPONENTS in 16134 U.S. 377, DUBLIN, TX 76446 (NAICS 332311). OSHA activity number 347696502.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Prime Metal Buildings & Components — free Get an email when a new federal OSHA severe-injury report for Prime Metal Buildings & Components is published. One employer, no account, unsubscribe in one click.
Site address
16134 U.S. 377
City
DUBLIN
State
TX
ZIP
76446
Mailing
16134 U.S. 377, DUBLIN, TX 76446
Inspection type
Complaint (B)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332311
Employees
78
Ownership type
A

10 citations on file for this inspection.

1910.134 C01

Deleted Serious Gravity 5 1 instance 2 exposed
Issued
Nov 13, 2024
Abate by
Nov 22, 2024
Penalty
Initial $9,680 · Current $0 Reduced
29 CFR 1910.134(c)(1): A written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not established and implemented for required respirator use:  On or about August 2, 2024, the employer did not evaluate and provide respiratory protection program for employee(s) spray painting using Adams Paint PPG in Light Gray and Red.
Recent events (2)
  • — I (S) $0
  • — Z (S) $9680

1910.178 L01 I

Serious Gravity 10 1 instance 1 exposed
Issued
Nov 13, 2024
Abate by
Dec 20, 2024
Penalty
Initial $11,292 · Current $7,900 Reduced
29 CFR 1910.178(l)(1)(i): The employer did not ensure that each powered industrial truck operator was competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l):  On or about August 2, 2024, in the shipping department, employees who were not trained operated a Toyota forklift.
Recent events (2)
  • — I (S) $7900
  • — Z (S) $11292

1910.179 J03

Deleted Serious Gravity 5 1 instance 4 exposed
Issued
Nov 13, 2024
Abate by
Nov 22, 2024
Penalty
Initial $9,680 · Current $0 Reduced
29 CFR  1910.179(j)(3): Complete inspections of the crane was not being performed at intervals as generally defined in paragraph (j)(1)(ii)(b) of this section:  On or about August 2, 2024, in the welding department, the employer did not ensure monthly inspections were being performed on the FIM 1-ton overhead crane, and a 4 Ton Proser overhead crane.
Recent events (2)
  • — I (S) $0
  • — Z (S) $9680

1910.179 G01 V

Other-than-serious Gravity 5 1 instance 1 exposed
Issued
Nov 13, 2024
Abate by
Dec 20, 2024
Penalty
Initial $6,453 · Current $5,000 Reduced
29 CFR  1910.179(g)(1)(v): Pendant control boxes shall be constructed to prevent electrical shock and shall be clearly marked for identification of functions.   On or about August 2, 2024, in the welding department, a pendant control box was missing a cover to identify the functions of the 4-ton Proser overhead crane.
Recent events (2)
  • — I (O) $5000
  • — Z (S) $6453

1910.184 H05 III

Serious Gravity 5 1 instance 2 exposed
Issued
Nov 13, 2024
Abate by
Dec 20, 2024
Penalty
Initial $9,680 · Current $6,776 Reduced
29 CFR 1910.184(h)(5)(iii): Natural or synthetic fiber rope sling(s) with broken or cut fibers were not immediately removed from service:  On or about August 2, 2024, in the Paint Department, employees used a 3-foot-wide synthetic fiber sling that was severely cut and frayed.
Recent events (2)
  • — I (S) $6776
  • — Z (S) $9680

1910.243 C04

Deleted Serious Gravity 5 1 instance 1 exposed
Issued
Nov 13, 2024
Abate by
Nov 22, 2024
Penalty
Initial $9,680 · Current $0 Reduced
29 CFR  1910.243(c)(4): The angular exposure on the grinding wheel periphery and sides for safety guard(s) used on portable grinding machine(s) exceeded 180 degrees:  On or about August 2, 2024, in the welding department employees used a DeWalt right hand angle grinder without a guard.
Recent events (2)
  • — I (S) $0
  • — Z (S) $9680

1910.303 F02

Deleted Serious Gravity 5 1 instance 1 exposed
Issued
Nov 13, 2024
Abate by
Nov 22, 2024
Penalty
Initial $6,453 · Current $0 Reduced
29 CFR 1910.303(f)(2): Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, was not legibly marked to indicate its purpose, nor located and arranged so the purpose was evident:  On or about August 2, 2024,  in the robotic area, breakers in the electrical panel box were not identified as to what they controlled.
Recent events (2)
  • — I (S) $0
  • — Z (S) $6453

1910.305 G02 II

Serious Gravity 5 1 instance 1 exposed
Issued
Nov 13, 2024
Abate by
Dec 20, 2024
Penalty
Initial $6,453 · Current $4,517 Reduced
29 CFR 1910.305(g)(2)(ii): Flexible cords were not used only in continuous lengths without splice or tap:  On or about August 2, 2024, in the welding department, the power cord to the Airmate 30" floor fan was severely cut, frayed on several places on the cord, exposing employees to the hazard of electrical burns and shock.
Recent events (2)
  • — I (S) $4517
  • — Z (S) $6453

1910.37 B02

Other-than-serious 1 instance 1 exposed
Issued
Nov 13, 2024
Abate by
Nov 22, 2024
Penalty
Initial $0 · Current $0
29 CFR  1910.37(b)(2): Each exit was not clearly visible and marked by a sign reading "Exit":   On or about August 2, 2024, in the Plasma Department there was no exit sign provided over the door leading to the outside of the building.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.157 C01

Other-than-serious 1 instance 1 exposed
Issued
Nov 13, 2024
Abate by
Nov 22, 2024
Penalty
Initial $0 · Current $0
29 CFR 1910.157(c)(1): Portable fire extinguishers were not mounted, located and identified so that they were readily accessible without subjecting the employees to injuries:  On or about August 2, 2024, in the welding department, the Ansul Sentry fire extinguisher was not mounted.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347696502.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.