Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: ADVANCED DRAINAGE SYSTEMS, INC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of ADVANCED DRAINAGE SYSTEMS, INC in 58 WYOMING STREET, LUDLOW, MA 01056 (NAICS 326122). OSHA activity number 347696668.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Advanced Drainage Systems, INC — free Get an email when a new federal OSHA severe-injury report for Advanced Drainage Systems, INC is published. One employer, no account, unsubscribe in one click.
Site address
58 WYOMING STREET
City
LUDLOW
State
MA
ZIP
01056
Mailing
58 WYOMING STREET, LUDLOW, MA 01056
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
326122
Employees
105
Ownership type
A

1 citation on file for this inspection.

1910.147 C06 I

Other-than-serious 1 instance 20 exposed
Issued
Dec 5, 2024
Abate by
Jan 24, 2025
Penalty
Initial $0 · Current $0
29 CFR  1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed:   58 Wyoming Street, Ludlow, MA: On and before August 19, 2024, the employer had not performed a comprehensive periodic inspection of their energy control procedures for all multi-energy source machines, including but not limited to the Line 3640 Corrugator, at least annually to verify that each procedure was adequate and being properly used by employees.  *Abatement Notes:  A periodic inspection shall include the following elements:  - Appointment of an authorized employee to inspect each local procedure for inaccuracies during an energy control task - A review by inspector with each authorized employee, of that employee's responsibilities under each energy control procedure they are authorized to use - Certification that the periodic inspections have been performed by identifying the machines or equipment on which the energy control procedures were being utilized, the dates of the inspections, the employees included in the inspections, and the persons performing the inspections *Abatement notes are intended only to provide clarity regarding existing requirements under the law or agency policies. Abatement notes do not create (or diminish) legal obligations under the Occupational Safety and Health Act.
Recent events (1)
  • — Z (O) $0

View Advanced Drainage Systems, INC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347696668.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.