Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: MINISO

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of MINISO in 379 MAINE MALL ROAD, SOUTH PORTLAND, ME 04106 (NAICS 453998). OSHA activity number 347697427.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Miniso — free Get an email when a new federal OSHA severe-injury report for Miniso is published. One employer, no account, unsubscribe in one click.
Establishment
MINISO
Site address
379 MAINE MALL ROAD
City
SOUTH PORTLAND
State
ME
ZIP
04106
Mailing
379 MAINE MALL ROAD, SOUTH PORTLAND, ME 04106
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
453998
Employees
3
Ownership type
A

7 citations on file for this inspection.

1910.157 C01

Serious Gravity 1 1 instance 3 exposed
Issued
Sep 12, 2024
Abate by
Sep 24, 2024
Penalty
Initial $6,222 · Current $3,733 Reduced
29 CFR 1910.157(c)(1): Portable fire extinguishers were not mounted, located, and identified so that they were readily accessible without subjecting employees to injuries:  Storage Room - A portable fire extinguisher was not mounted and identified.
Recent events (2)
  • — I (S) $3733.2
  • — Z (S) $6222

1910.157 G01

Serious Gravity 1 1 instance 3 exposed
Issued
Sep 12, 2024
Penalty
Initial $6,222 · Current $3,733 Reduced
29 CFR 1910.157(g)(1): Where the employer provided portable fire extinguishers for employee use, the employer did not provide an educational program to familiarize employees with the general principles of fire extinguisher use and the hazards involved with incipient stage firefighting:  Facility - The employer did not provide an educational program for employees where portable fire extinguishers were provided for employee use.
Recent events (2)
  • — I (S) $3733.2
  • — Z (S) $6222

1910.303 G01

Serious Gravity 1 2 instances 3 exposed
Issued
Sep 12, 2024
Penalty
Initial $6,222 · Current $3,733 Reduced
29 CFR 1910.303(g)(1): Sufficient access and working space was not provided and maintained around all electric equipment (operating at 600 volts, nominal, or less to ground) to permit ready and safe operation and maintenance of such equipment:  Storage Room - Sufficient access and working space were not provided and maintained around the quick disconnect and breaker panel.
Recent events (2)
  • — I (S) $3733.2
  • — Z (S) $6222

1910.303 F02

Serious Gravity 1 1 instance 3 exposed
Issued
Sep 12, 2024
Penalty
Initial $0 · Current $0
29 CFR 1910.303(f)(2): Each service, feeder, or branch circuit, at its disconnecting means or overcurrent device, was not legibly marked to indicate its purpose or located and arranged so the purpose was evident:  Storage Room - A 200-amp, 240-volt Square D quick disconnect was not legibly marked to indicate its purpose or located and arranged so the purpose was evident.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1904.32 A03

Other-than-serious 1 instance 3 exposed
Issued
Sep 12, 2024
Abate by
Sep 23, 2024
Penalty
Initial $0 · Current $0
29 CFR 1904.32(a)(3): At the end of the calendar year, the employer did not certify the OSHA 300A form or it's equivalent:  Facility - At the end of the 2023 calendar year, the employer did not certify the OSHA 300A form by completing the certification section on the bottom right side.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1904.32 B02 II

Other-than-serious 1 instance 3 exposed
Issued
Sep 12, 2024
Abate by
Sep 24, 2024
Penalty
Initial $0 · Current $0
29 CFR 1904.32(b)(2)(ii): The annual summary did not include one or more of the following elements: the calendar year covered, the company's name, establishment name, establishment address, annual average number of employees, and the total hours worked by all employees:  Facility - The 2023 OSHA 300A submitted listed 0 employees and 0 hours worked at the establishment.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.157 E02

Other-than-serious 3 instances 2 exposed
Issued
Sep 12, 2024
Abate by
Sep 23, 2024
Penalty
Initial $0 · Current $0
29 CFR 1910.157(e)(2): Portable fire extinguishers were not visually inspected at least monthly:  Facility - Three fire portable extinguishers in the facility that were not visually inspected at least monthly.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347697427.