EL PASO, TX —
OSHA Inspection: JC ENVIRONMENTAL, INC.
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of JC ENVIRONMENTAL, INC. in 10701 VISTA DEL SOL DR. BUILDING G, EL PASO, TX 79935 (NAICS 236116). OSHA activity number 347703654.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- JC ENVIRONMENTAL, INC.
- Site address
- 10701 VISTA DEL SOL DR. BUILDING G
- City
- EL PASO
- State
- TX
- ZIP
- 79935
- Mailing
- 117 POLO INN RD., EL PASO, TX 79915
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236116
- Employees
- 11
- Ownership type
- A
Citations
5 citations on file for this inspection.
1903.19 D01
- Issued
- Feb 10, 2025
- Abate by
- Mar 28, 2025
- Penalty
- Initial $531 · Current $531
General-duty citation text
29 CFR 1903.19(d)(1): The employer did not submit to the Agency documents demonstrating that abatement is complete for each willful or repeat violation and for any serious violation for which the Agency indicates in the citation that such abatement documentation is required. a) On or about February 10, 2025, the employer did not submit documentation and Certification of Corrective Action for citation 1 item 3 issued on December 3, 2024, with an abatement due date of January 15, 2025. b) On or about February 10, 2025, the employer did not submit documentation and Certification of Corrective Action for citation 1 item 4 issued on December 3, 2024, with an abatement due date of January 15, 2025.
Recent events (1)
- — Z (O) $531
1926.403 B02
- Issued
- Dec 3, 2024
- Penalty
- Initial $4,610 · Current $3,500 Reduced
General-duty citation text
29 CFR 1926.403(b)(2): Listed, labeled, or certified equipment was not installed and used in accordance with instructions included in the listing, labeling, or certification. On or about August 22, 2024, at Building G Apartments 97-112; employees utilized a series of extension cords that were connected to each other (daisy chaining) to provide electrical power to an air conditioner installed at one of the apartments used as supervisor's office.
Recent events (2)
- — I (S) $3500
- — Z (S) $4610
1926.405 G02 IV
- Issued
- Dec 3, 2024
- Abate by
- Dec 13, 2024
- Penalty
- Initial $2,765 · Current $0 Reduced
9020
General-duty citation text
29 CFR 1926.405(g)(2)(iv): Flexible cords were not connected to devices and fittings so that strain relief is provided to prevent pull from being directly transmitted to joints or terminal screws: On or above August 22, 2024, at Building G Apartments 970112; employees used an electrical-powered-flexible cord with a broken strain relief.
Recent events (2)
- — I (S) $0
- — Z (S) $2765
1926.1101 F05
- Issued
- Dec 3, 2024
- Abate by
- Jan 15, 2025
- Penalty
- Initial $5,531 · Current $3,500 Reduced
9020
General-duty citation text
29 CFR 1926.1101(f)(5): The employer did not notify, as soon as possible nor within 5 working days of receipt of results, each affected employee of any monitoring performed under this section: On or about August 22, 2024, on Building G Apartments 97-112; the employees removing asbestos containing materials at the location were not notified by employer of their asbestos personal monitoring results within 5 days after results were received.
Recent events (2)
- — I (O) $3500
- — Z (S) $5531
1926.1101 G05 I A 3
- Issued
- Dec 3, 2024
- Abate by
- Jan 15, 2025
- Penalty
- Initial $3,687 · Current $1,500 Reduced
9020
General-duty citation text
29 CFR 1926.1101(g)(5)(i)(A)(3): A minimum of -0.02 column inches of water pressure differential relative to outside pressure were not maintained within the negative pressure enclosure as evidenced by manometric measurements: On or above August 22, 2024, at Building G Apartments 97-112; employees removing asbestos containing materials and presumed asbestos containing materials worked in an atmosphere where the negative pressure of -0.020 inches of water column was not maintained.
Recent events (2)
- — I (S) $1500
- — Z (S) $3687
More inspections at JC Environmental, INC.
View JC Environmental, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 236116)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347703654.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.