OSHA Inspection: PACTIVEVERGREEN, INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of PACTIVEVERGREEN, INC. in 3000 PEGASUS DRIVE, TEMPLE, TX 76501 (NAICS 326140). OSHA activity number 347706491.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Pactivevergreen, INC. — free Get an email when a new federal OSHA severe-injury report for Pactivevergreen, INC. is published. One employer, no account, unsubscribe in one click.
Site address
3000 PEGASUS DRIVE
City
TEMPLE
State
TX
ZIP
76501
Mailing
3000 PEGASUS DRIVE, TEMPLE, TX 76501
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
326140
Employees
276
Ownership type
A

5 citations on file for this inspection.

1910.147 A02 II B

Serious Gravity 10 1 instance 1 exposed
Issued
Jan 27, 2025
Abate by
Feb 21, 2025
Penalty
Initial $16,550 · Current $14,583 Reduced
29 CFR 1910.147(a)(2)(ii)(B): Lockout/tagout procedures were not implemented when servicing and/or maintenance was taking place during normal production operations when an employee was required to place any part of his/her body into an area on a machine or piece of equipment's point of operation.  On or about August 14, 2024, an employee operating a Gloucester 4500 series reclaim extruder was feeding a piece of scrap material into the running machine and did not follow company procedure to use a poly bar but unexpectedly reached their arm into the running machine and contacted the screw auger. was attempting to clear a jam without de-energizing the equipment.
Recent events (2)
  • — I (S) $14583
  • — Z (S) $16550

1910.147 C06 I

Serious Gravity 5 1 instance 1 exposed
Issued
Jan 27, 2025
Abate by
Feb 21, 2025
Penalty
Initial $11,823 · Current $10,417 Reduced
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed.   On or about August 14, 2024, the employer did not fully certify that a periodic inspection was conducted for an authorized employee, Sidney Johnson, on the Gloucester 4500 series reclaim extruder.
Recent events (2)
  • — I (S) $10417
  • — Z (S) $11823

1910.157 C01

Deleted Serious Gravity 1 2 instances 300 exposed
Issued
Jan 27, 2025
Abate by
Feb 21, 2025
Penalty
Initial $7,093 · Current $0 Reduced
29 CFR 1910.157(c)(1): A portable fire extinguisher was blocked or missing and not available for immediate use by employees.  On or about August 22, 2024, and at times prior thereto, employees were exposed to fire hazards due to blocked or missing fire extinguishers.
Recent events (2)
  • — I (S) $0
  • — Z (S) $7093

1910.304 F01 IV

Deleted Serious Gravity 1 5 instances 300 exposed
Issued
Jan 27, 2025
Abate by
Feb 21, 2025
Penalty
Initial $7,093 · Current $0 Reduced
29 CFR 1910.304(f)(1)(iv): Over-current devices were not readily accessible to each employee or authorized building management personnel.  On or about August 22, 2024, and at times prior thereto, knife switch control panels and electrical breaker boxes were blocked from quick and ready access.
Recent events (2)
  • — I (S) $0
  • — Z (S) $7093

1910.334 A02 I

Deleted Serious Gravity 5 1 instance 300 exposed
Issued
Jan 27, 2025
Abate by
Feb 21, 2025
Penalty
Initial $9,457 · Current $0 Reduced
29 CFR 1910.334(a)(2)(i): Portable cord and plug connected equipment and flexible cord sets (extension cords) were not visually inspected before use on any shift for external defects (such as loose parts, deformed and missing pins, or damage to outer jacket or insulation) and for evidence of possible internal damage (such as pinched or crushed outer jacket).  On or about August 22, 2024, and at times prior thereto, employees were exposed to an electrical hazard from extension cords being used with visible damage without being inspected prior to use.
Recent events (2)
  • — I (S) $0
  • — Z (S) $9457

View Pactivevergreen, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347706491.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.