Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: NITTERHOUSE MASONRY PRODUCTS, LLC

Follow-up inspection · Safety discipline

On , OSHA opened a follow-up safety inspection of NITTERHOUSE MASONRY PRODUCTS, LLC in 859 CLEVELAND AVENUE, CHAMBERSBURG, PA 17201 (NAICS 327390). OSHA activity number 347708810.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Nitterhouse Masonry Products, LLC — free Get an email when a new federal OSHA severe-injury report for Nitterhouse Masonry Products, LLC is published. One employer, no account, unsubscribe in one click.
Site address
859 CLEVELAND AVENUE
City
CHAMBERSBURG
State
PA
ZIP
17201
Mailing
859 CLEVELAND AVENUE, CHAMBERSBURG, PA 17201
Inspection type
Follow-up (F)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
327390
Employees
30
Ownership type
A

4 citations on file for this inspection.

1910.23 D07

Deleted Serious Gravity 1 1 instance 1 exposed
Issued
Dec 2, 2024
Abate by
Dec 19, 2024
Penalty
Initial $4,839 · Current $0 Reduced
29 CFR 1910.23(d)(7): The employer did not ensure that grab bars extend 42 inches (1.1 m) above the access level or landing platforms served by the ladder.  (a) 859 Cleveland Ave, Chambersburg, PA; Mixer pit - On or about August 23, 2024, the access ladder into the mixer pit did not extend above the floor level to provide a handhold when entering or exiting the 5-foot-deep mixer pit.   Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (S) $0
  • — Z (S) $4839

1910.28 B01 I

Other-than-serious Gravity 1 1 instance 1 exposed
Issued
Dec 2, 2024
Abate by
Dec 19, 2024
Penalty
Initial $0 · Current $4,000
29 CFR  1910.28(b)(1)(i): Except as provided elsewhere in this section 29 CFR 1910.28, the employer did not ensure that each employee on a walking-working surface with an unprotected side or edge that is 4 feet (1.2 m) or more above a lower level is protected from falling by one or more of the systems described in 29 CFR 1910.28(b)(1)(i):   (a) 859 Cleveland Ave, Chambersburg, PA; Mixer pit - On or about August 23, 2024, the mixer pit was unguarded at one side which was approximately 10-feet across creating a fall hazard of approximately 5-feet into the mixer pit.  Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (O) $4000
  • — Z (S) $0

1910.303 B08 I

Other-than-serious Gravity 1 1 instance 1 exposed
Issued
Dec 2, 2024
Penalty
Initial $4,839 · Current $4,000 Reduced
29 CFR  1910.303(b)(8)(i): Electric equipment was not firmly secured to the surface on which it was mounted:  (a) 859 Cleveland Ave, Chambersburg, PA; on the wall behind the Mixer pit - On or about August 23, 2024, the light fixture for the Mixer pit was not securely mounted to the wall.  No abatement certification required.
Recent events (2)
  • — I (O) $4000
  • — Z (S) $4839

1910.305 B02 I

Other-than-serious Gravity 1 1 instance 1 exposed
Issued
Dec 2, 2024
Penalty
Initial $0 · Current $0
29 CFR  1910.305(b)(2)(i): Each outlet box in completed installations did not have a cover, faceplate, or fixture canopy:  (a) 859 Cleveland Ave, Chambersburg, PA; support beams in next to the Mixer Pit - On or about August 23, 2024, three electrical junction boxes did not have the cover or faceplate in place over the electrical wiring.   No abatement certification required.
Recent events (2)
  • — I (O) $0
  • — Z (S) $0

View Nitterhouse Masonry Products, LLC's full OSHA safety record →