OSHA Inspection: CURRENT ELECTRICAL CONTRACTORS, INC.

Federal Agency inspection · Safety discipline

On , OSHA opened a federal Agency safety inspection of CURRENT ELECTRICAL CONTRACTORS, INC. in 3306 CENTRAL STREET, EVANSTON, IL 60201 (NAICS 238210). OSHA activity number 347712937.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Current Electrical Contractors, INC. — free Get an email when a new federal OSHA severe-injury report for Current Electrical Contractors, INC. is published. One employer, no account, unsubscribe in one click.
Site address
3306 CENTRAL STREET
City
EVANSTON
State
IL
ZIP
60201
Mailing
1946-D LEHIGH AVENUE, GLENVIEW, IL 60026
Inspection type
Federal Agency (M)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238210
Employees
2
Ownership type
A

1 citation on file for this inspection.

1926.416 A01

Serious Gravity 10 1 instance 2 exposed
Issued
Jan 21, 2025
Abate by
Mar 31, 2025
Penalty
Initial $6,620 · Current $6,620
29 CFR  1926.416(a)(1): The employer permitted employees to work in close proximity to energized, unguarded, and ungrounded electric power circuits that the employee could contact in the course of their work:   (a) On or about August 26, 2024, an employee installing lighting was exposed to electrical shock while working around exposed electrical parts with a voltage of 120 volts.  (b) On or about August 22, 2024, employees installing residential electrical service were exposed to electrical shock while working around exposed electrical parts with a voltage of 120/240 volts.  In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement or other written records.