Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: KINETIC ENERGY SERVICES, LLC

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of KINETIC ENERGY SERVICES, LLC in 16923 BEAUMONT HWY, HOUSTON, TX 77049 (NAICS 488210). OSHA activity number 347713695.

Watch Kinetic Energy Services, LLC — free Get an email when a new federal OSHA severe-injury report for Kinetic Energy Services, LLC is published. One employer, no account, unsubscribe in one click.
Site address
16923 BEAUMONT HWY
City
HOUSTON
State
TX
ZIP
77049
Mailing
541 GARDEN DR. UNIT L, WINDSOR, CO 80550
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
488210
Employees
11
Ownership type
A

6 citations on file for this inspection.

1910.134 C01

Other-than-serious Gravity 5 1 instance 13 exposed
Issued
Abate by
Penalty
Initial $10372.00 · Current $10372.00
29 CFR  1910.134(c)(1): A written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not established and implemented for required respirator use:  On or�about August 26, 2024,�in the�interior blast and cleaning rack area,�employees wore supplied-air respirators and full-face respirators�while blasting and cleaning�without the�employer having�an established�written respiratory�protection program.
Recent events (3)
  • — F (O) $10372
  • — C (S) $10372
  • — Z (S) $10372

1910.134 F02

Other-than-serious Gravity 5 1 instance 5 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.134(f)(2): Employee(s) using a tight-fitting facepiece respirator were not annually fit tested:   On or�about August 26, 2024,�in the�cleaning rack area,�employees wore full-face respirators�while cleaning�without the�employees being fit tested.
Recent events (3)
  • — F (O) $0
  • — C (S) $0
  • — Z (S) $0

1910.134 I07

Other-than-serious Gravity 5 1 instance 8 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.134(i)(7): Oil lubricated compressor(s) used to supply breathing air did not have a high-temperature or carbon monoxide alarm(s) or both:   On or about August 26, 2024, in the interior blast, employees wore supplied-air respirators, and the employer did not maintain calibration for the carbon monoxide alarm for the supplied breathing air from an oil lubricated compressor. The system did not have a high-temperature alarm.
Recent events (3)
  • — F (O) $0
  • — C (S) $0
  • — Z (S) $0

1910.134 K

Other-than-serious Gravity 5 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.134(k): The employer did not provide comprehensive, understandable training which did not occur annually and/or more often if necessary:   On or�about August 26, 2024,�at the cleaning rack area,�employees wore full-face respirators�while cleaning�without having been provided respirator training.
Recent events (3)
  • — F (O) $0
  • — C (S) $0
  • — Z (S) $0

1910.146 K03

Deleted Serious Gravity 5 1 instance 13 exposed
Issued
Penalty
Initial $10372.00 · Current $0.00 Reduced
29 CFR  1910.146(k)(3): A retrieval system or methods were not used to facilitate non-entry rescue when an authorized entrant entered a permit space:     On or about August 26, 2024, at the interior blast area and cleaning rack, employees entered into rail tank cars, which were permit spaces, to abrasively blast and clean and did not utilize a retrieval system or methods to facilitate non-entry rescue.
Recent events (3)
  • — F (S) $0
  • — C (S) $10372
  • — Z (S) $10372

1910.134 I05 IV

Other-than-serious 1 instance 8 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.134(i)(5)(iv):The employer did not ensure that compressors used to supply breathing air to respirators were constructed and situated so as to have a tag maintained at the compressor containing the most recent change date and the signature of the person authorized by the employer to perform the change:  On or about August 26, 2024, at the interior blast area, employees used supplied-air respirators but the employer did not maintain a tag indicating the most recent change date for the in-line filter and the signature of the person who performed the change.