OKLAHOMA CITY, OK —
OSHA Inspection: MOHAWK MATERIALS CO., INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of MOHAWK MATERIALS CO., INC. in 8300 N.W. 3RD ST., OKLAHOMA CITY, OK 73127 (NAICS 561910). OSHA activity number 347718090.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- MOHAWK MATERIALS CO., INC.
- Site address
- 8300 N.W. 3RD ST.
- City
- OKLAHOMA CITY
- State
- OK
- ZIP
- 73127
- Mailing
- 201 COOLEY DRIVE, OKLAHOMA CITY, OK 73127
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Last modified
- Data loaded
Establishment context
- NAICS code
- 561910
- Employees
- 10
- Ownership type
- A
Citations
10 citations on file for this inspection.
1910.29 B01
- Issued
- Feb 19, 2025
- Abate by
- Mar 31, 2025
- Penalty
- Initial $4,965 · Current $3,000 Reduced
General-duty citation text
29 CFR 1910.29(b)(1): The employer did not ensure that guardrail systems met the requirement that the top edge height of top rails, or equivalent guardrail system members, that are 42 inches (107 cm), plus or minus 3 inches (8 cm), above the walking-working surface. The top edge height may exceed 45 inches (114 cm), provided the guardrail system meets all other criteria of paragraph (b) of this section (see Figure D-11 of this section). On or about August 28, 2024, and at times prior, at an outdoor platform for a sand conveyor, the top edge height of the platform's top rails were less than 42 inches (107 cm) above the platform's floor. The platform was 4 feet above a lower level and was available for employee access for motor maintenance.
Recent events (2)
- — I (S) $3000
- — Z (S) $4965
1910.29 B02
- Issued
- Feb 19, 2025
- Abate by
- Mar 31, 2025
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.29(b)(2): The employer did not ensure that guardrail systems met the requirement that mid-rails, screens, mesh, intermediate vertical members, solid panels, or equivalent intermediate members were installed between the walking-working surface and the top edge of the guardrail system. On or about August 28, 2024, and at times prior, an outdoor platform for a sand conveyor lacked mid-rails between the platform's floor and its top guardrails. The platform was 4 feet above a lower level and was available for employee access for motor maintenance.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.147 C07 I
- Issued
- Feb 19, 2025
- Abate by
- Mar 31, 2025
- Penalty
- Initial $6,620 · Current $4,000 Reduced
General-duty citation text
29 CFR 1910.147(c)(7)(i): The employer did not provide adequate training to ensure that the purpose and function of the energy control program was understood by employees: On or about August 21, 2024, at the sand lift conveyor, an employee performed maintenance on a conveyor belt and did not receive adequate training on the purpose and function of the energy control program.
Recent events (2)
- — I (S) $4000
- — Z (S) $6620
1910.147 D02
- Issued
- Feb 19, 2025
- Abate by
- Mar 31, 2025
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(d)(2): The machine or equipment was not turned off or shut down using the procedures established for the machine or equipment: On or about August 21, 2024, at the sand lift conveyor, an employee performed maintenance on a conveyor belt and did not shut down the conveyor using the lockout tagout procedure.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.212 A01
- Issued
- Feb 19, 2025
- Abate by
- Mar 12, 2025
- Penalty
- Initial $6,620 · Current $0 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: a. On or about August 21, 2024, and at times prior, at the sand lift conveyor, a guard was not installed for the conveyor belt and lower conveyor roller which created an in-going nip point where an employee was caught by the conveyor belt and lower roller. b. On or about August 21, 2024, and at times prior, at a platform of the sand lift conveyor, a guard was not installed for the conveyor belt and upper conveyor roller which created an in-going nip point and exposed employees to caught-by hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $6620
1910.305 A02 IX
- Issued
- Feb 19, 2025
- Abate by
- Mar 31, 2025
- Penalty
- Initial $4,965 · Current $3,000 Reduced
General-duty citation text
29 CFR 1910.305(a)(2)(ix): All lamps for general illumination were not protected from accidental contact or breakage by a suitable fixture or lamp holder with a guard: On or about August 28, 2024, in the electrical control room, by an equipment control box used by employees, a pendant light had no cover or guard for the light bulb and was less than 7 feet from the walking/working surface.
Recent events (2)
- — I (S) $3000
- — Z (S) $4965
1910.305 B02 I
- Issued
- Feb 19, 2025
- Abate by
- Mar 31, 2025
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(b)(2)(i): Pull boxes, junction boxes, and fittings were not provided with covers approved for the purpose: On or about August 28, 2024, in the electrical control room, there was no cover at an unused opening of a conduit body which held electrical wires that entered an equipment control box used by employees.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.305 G01 IV
- Issued
- Feb 19, 2025
- Abate by
- Mar 12, 2025
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(1)(iv): Flexible cords and/ or cables were used for purposes prohibited by paragraphs (A) through (F) of 29 CFR 1910.305(g)(1)(iv)(a): On or about August 28, 2024, in the electrical control room, flexible cords were used as a substitute for fixed wiring and were wrapped or draped on conduit which exposes employees to electrical hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1904.39 A02
- Issued
- Feb 19, 2025
- Abate by
- Mar 12, 2025
- Penalty
- Initial $8,276 · Current $4,000 Reduced
General-duty citation text
29 CFR 1904.39(a)(2):The employer did not report within 24-hours a work-related incident resulting in in-patient hospitalization, amputation or the loss of an eye. An in-patient hospitalization of one (1) employee, occurring on or about August 21, 2024, was not reported to OSHA within the 24-hour reporting requirement.
Recent events (2)
- — I (O) $4000
- — Z (O) $8276
1910.219 C04 I
- Issued
- Feb 19, 2025
- Abate by
- Mar 12, 2025
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.219(c)(4)(i): Unguarded projecting shaft end(s) did not present a smooth edge and end and projected more than one half the diameter of the shaft: On or about August 28, 2024, and at times prior, at the sand lift conveyor platform, the end of a conveyor shaft projected out more than one half the diameter of the shaft and was not guarded to prevent employees from contacting the rotating shaft end.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Mohawk Materials CO., INC.
View Mohawk Materials CO., INC.'s full OSHA safety record →
More inspections in this industry (NAICS 561910)
More inspections in OK
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347718090.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.