Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: DERAWAY CONSTRUCTION

Unprogrammed Other inspection · Safety discipline

On , OSHA opened an unprogrammed Other safety inspection of DERAWAY CONSTRUCTION in 418 ROBERTS STREET, ROME, NY 13440 (NAICS 238160). OSHA activity number 347720492.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Deraway Construction — free Get an email when a new federal OSHA severe-injury report for Deraway Construction is published. One employer, no account, unsubscribe in one click.
Site address
418 ROBERTS STREET
City
ROME
State
NY
ZIP
13440
Mailing
7264 VIENNA ROAD, BLOSSVALE, NY 13308
Inspection type
Unprogrammed Other (I)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Last modified
Data loaded
NAICS code
238160
Employees
4
Ownership type
A

7 citations on file for this inspection.

1903.19 D01

Other-than-serious 1 instance 2 exposed
Issued
Sep 25, 2025
Abate by
Nov 13, 2025
Penalty
Initial $398 · Current $398
29 CFR  1903.19(d)(1): The employer did not submit to the Agency documents demonstrating that abatement is complete for each willful or repeat violation and for any serious violation for which the Agency indicates in the citation that such abatement documentation is required.   a) 418 Roberts Street, Rome, NY  13440, on the scaffold, on or about 8/27/24:  Employees were working from a ladder-jack scaffold, 16 feet from ground, without fall protection of any kind, and the metal scaffold components were placed within 6 inches of the live power feed into the building demonstrating that the employer failed to retrain employees that showed indications through work performance of not retaining the requisite proficiency.  Abatement documentation was required for this item and not provided.    Abatement documentation must be submitted for this item.
Recent events (1)
  • — Z (O) $398

1926.454 C03

Serious Gravity 10 1 instance 2 exposed
Issued
Feb 21, 2025
Abate by
Jul 9, 2025
Penalty
Initial $4,965 · Current $3,476 Reduced
1926.454(c)(3): The employer failed to retrain employees that showed indications through work performance of not retaining the requisite proficiency:   a) 418 Roberts Street, Rome, NY  13440, on the scaffold, on or about 8/27/24:  Employees were working from a ladder-jack scaffold, 16 feet from ground, without fall protection of any kind, and the metal scaffold components were placed within 6 inches of the live power feed into the building.  Abatement documentation must be submitted for this item.
Recent events (3)
  • — F (S) $3476
  • — C (S) $4965
  • — Z (S) $4965

1926.451 F06

Serious Gravity 10 1 instance 2 exposed
Issued
Feb 21, 2025
Penalty
Initial $0 · Current $0
29 CFR  1926.451(f)(6): Scaffolds were erected, used, dismantled, altered, or moved such that they, or any conductive material handled on them, could have come closer than the minimum distances established for specific voltages as set forth in the table in subparagraph (f)(6):   a) 418 Roberts Street, Rome, NY  13440, on the scaffold, on or about 8/27/24:  Employees were working from a ladder-jack scaffold, 16 feet from ground, where the support ladder off-set and the scaffold pick was assembled within 6 inches of the buildings power feed.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

1926.451 G01

Serious Gravity 10 1 instance 2 exposed
Issued
Feb 21, 2025
Penalty
Initial $0 · Current $0
29 CFR  1926.451(g)(1):Each employee on a scaffold more than 10 feet above a lower level was not protected from falling to that lower level.  a) 418 Roberts Street, Rome, NY  13440, on the scaffold, on or about 8/27/24:  Employees were working from a ladder-jack scaffold, 16 feet from ground, without fall protection of any kind.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

1926.501 B13

Serious Gravity 10 1 instance 1 exposed
Issued
Feb 21, 2025
Penalty
Initial $4,965 · Current $0 Reduced
29 CFR  1926.501(b)(13): Each employee engaged in residential construction activities 6 feet (1.8 m)  or more above lower levels was not protected by guardrail systems, safety net systems, personal fall arrest systems, or an alternative fall protection measure under another provision of paragraph 1926.501(b), nor did the employer demonstrate that it is infeasible or creates a greater hazard to use these systems and develop and implement a fall protection plan which meets the requirements of paragraph (k) of section 1926.502:    a) 418 Roberts Street, Rome, NY  13440, on the roof, on or about 8/27/24:  an employee was installing roofing material along the ridge of a 7:12 pitch roof, with a ground to eave height of 18 feet, and without fall protection of any kind.
Recent events (3)
  • — F (S) $0
  • — C (S) $4965
  • — Z (S) $4965

1926.1053 B01

Serious Gravity 5 2 instances 2 exposed
Issued
Feb 21, 2025
Penalty
Initial $3,547 · Current $0 Reduced
29 CFR  1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed:    a) 418 Roberts Street, Rome, NY  13440, on or about 8/27/24:  An employee was installing roofing material along the ridge of a 7:12 pitch roof, with a ground to eave height of 18 feet, having accessed the roof via an extension ladder that did not extend at least 3 feet above the upper landing.    b)  418 Roberts Street, Rome, NY  13440, on or about 8/27/24:  Workers accessed a ladder-jack scaffold, 16 feet from ground, via an extension ladder that did not extend at least 3 feet above the upper landing.
Recent events (3)
  • — F (S) $0
  • — C (S) $3547
  • — Z (S) $3547

1926.1053 B05 I

Serious Gravity 1 1 instance 1 exposed
Issued
Feb 21, 2025
Penalty
Initial $0 · Current $0
29 CFR  1926.1053(b)(5)(i): Non-self-supporting ladders were not used at an angle such that the horizontal distance from the top support to the foot of the ladder was approximately one-quarter of the working length of the ladder (the distance along the ladder between the foot and the top support):   a) 418 Roberts Street, Rome, NY  13440, on or about 8/27/24:  An employee was installing roofing material along the ridge of a 7:12 pitch roof, with a ground to eave height of 18 feet, having accessed the roof via an extension ladder that was placed at an angle of approximately 51 degrees.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

View Deraway Construction's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347720492.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.