ITASCA, IL —
OSHA Inspection: PHOENIX CONVERTING, INC. DBA ADVANCED CONVERTING WORKS DBA FLEX PACK
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of PHOENIX CONVERTING, INC. DBA ADVANCED CONVERTING WORKS DBA FLEX PACK in 1251 ARDMORE AVE, ITASCA, IL 60143 (NAICS 326111). OSHA activity number 347723991.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Site address
- 1251 ARDMORE AVE
- City
- ITASCA
- State
- IL
- ZIP
- 60143
- Mailing
- 1251 ARDMORE AVE, ITASCA, IL 60143
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 326111
- Employees
- 61
- Ownership type
- A
Citations
6 citations on file for this inspection.
1910.147 C04 I
- Issued
- Dec 6, 2024
- Abate by
- Feb 3, 2025
- Penalty
- Initial $14,518 · Current $7,250 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(i):Procedures shall be developed, documented and utilized for the control of potentially hazardous energy when employees are engaged in the activities covered by this section. (a): On or about September 13, 2024, the employer did not develop, document, and utilize energy control procedures prior to allowing employees to perform servicing and maintenance activities on Pouch Line #13. Employees were exposed to caught-in and amputation injuries while performing adjustments to the equipment. Abatement certification is required of this item in accordance with the requirements of 29 CFR 1903.19(d).
Recent events (2)
- — I (S) $7250
- — Z (S) $14518
1910.212 A01
- Issued
- Dec 6, 2024
- Abate by
- Feb 3, 2025
- Penalty
- Initial $14,518 · Current $7,250 Reduced
General-duty citation text
29 CFR 1910.212(a)(1):Types of guarding. One or more methods of machine guarding shall be provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks. Examples of guarding methods are-barrier guards, two-hand tripping devices,electronic safety devices, etc. (a): On or about August 29, 2024, the employer did not ensure that machinery points of operation were guarded to protect employees from contact with the danger zone during the operating cycle. Employees operating Pouch Line #3 were exposed to amputation hazards from the sheer blade while operating. (b): On or about August 29, 2024, the employer did not ensure that machinery points of operation were guarded to protect employees from contact with the danger zone during the operating cycle. Employees operating Pouch Line #6 were exposed to amputation hazards from the sheer blade while operating. (c): On or about August 29, 2024, the employer did not ensure that machinery points of operation were guarded to protect employees from contact with the danger zone during the operating cycle. Employees operating Pouch Line #12 were exposed to amputation hazards from the sheer blade while operating. Abatement documentation is required for this item in accordance with 29 CFR 1903.19(d).
Recent events (2)
- — I (S) $7250
- — Z (S) $14518
1910.212 A03 II
- Issued
- Dec 6, 2024
- Abate by
- Feb 3, 2025
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.212(a)(3)(ii): The point of operation of machines whose operation exposes an employee to injury, shall be guarded. The guarding device shall be in conformity with any appropriate standards therefor, or, in the absence of applicable specific standards, shall be so designed and constructed as to prevent the operator from having any part of his body in the danger zone during the operating cycle. (a): On or about August 29, 2024, the employer did not ensure that machinery points of operation were guarded to protect employees from contact with the danger zone during the operating cycle. Employees operating Press Machine #2 were exposed to amputation hazards from the incoming nip points of rollers while operating. (b): On or about August 29, 2024, the employer did not ensure that machinery points of operation were guarded to protect employees from contact with the danger zone during the operating cycle. Employees operating Press Machine #3 were exposed to amputation hazards from the incoming nip points of rollers while operating. (c): On or about August 29, 2024, the employer did not ensure that machinery points of operation were guarded to protect employees from contact with the danger zone during the operating cycle. Employees operating Slitter #1 were exposed to amputation hazards from the incoming nip points of rollers while operating. Abatement documentation is required for this item in accordance with 29 CFR 1903.19(d).
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.305 G01 I
- Issued
- Dec 6, 2024
- Abate by
- Dec 30, 2024
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(1)(i):Flexible cords and cables shall be approved for conditions of use and location. (a): On or about August 29, 2024, the employer allowed for the use of damaged flexible electrical cords to connect Pouch Line #3 to the structure, exposing employees to fire and electrical shock hazards. Abatement documentation is required for this item in accordance with 29 CFR 1903.19(d).
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.305 G01 IV
- Issued
- Dec 6, 2024
- Abate by
- Dec 30, 2024
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(1)(iv): Unless specifically permitted otherwise in paragraph (g)(1)(ii) of this section, flexible cords and cables may not be used: 29 CFR 1910.305(g)(1)(iv)(A): As a substitute for the fixed wiring of a structure. (a): On or about August 29, 2024, the employer allowed for the use of flexible electrical cords to be used as a as a substitute for fixed wiring to connect Pouch Line #3 to the structure, exposing employees to fire and electrical shock hazards. Abatement documentation is required for this item in accordance with 29 CFR 1903.19(d).
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.305 G02 II
- Issued
- Dec 6, 2024
- Abate by
- Dec 30, 2024
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(2)(ii):Flexible cords may be used only in continuous lengths without splice or tap. Hard-service cord and junior hard-service cord No. 14 and larger may be repaired if spliced so that the splice retains the insulation, outer sheath properties, and usage characteristics of the cord being spliced. (c): On or about August 29, 2024, the employer did not ensure that flexible cords were used in continuous lengths without splice near Pouch Machine #6, exposing employees to shock hazards. A LED work lamp was modified to accept a two-prong flexible cord. Abatement certification is required of this item in accordance with the requirements of 29 CFR 1903.19(d).
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Phoenix Converting, INC. DBA Advanced Converting Works DBA Flex Pack
More inspections in this industry (NAICS 326111)
More inspections in IL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347723991.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.