PORT ARTHUR, TX —
OSHA Inspection: OXBOW CALCINING LLC
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of OXBOW CALCINING LLC in 3901 COKE DOCK RD., PORT ARTHUR, TX 77640 (NAICS 324199). OSHA activity number 347734741.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- OXBOW CALCINING LLC
- Site address
- 3901 COKE DOCK RD.
- City
- PORT ARTHUR
- State
- TX
- ZIP
- 77640
- Mailing
- PO BOX C, PORT ARTHUR, TX 77641
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 324199
- Employees
- 70
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.147 C04 I
- Issued
- Nov 7, 2024
- Abate by
- Dec 5, 2024
- Penalty
- Initial $6,222 · Current $3,733 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: a) On or about August 29, 2024, at Kiln 2 area, where the procedures were not developed for the control of potentially hazardous energy when employees were disconnecting the compressor's hose from the main air line.
Recent events (2)
- — I (S) $3733.2
- — Z (S) $6222
1910.147 D03
- Issued
- Nov 7, 2024
- Abate by
- Dec 5, 2024
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(d)(3): All energy isolating devices that were needed to control the energy to the machine or equipment were not physically located and operated in such a manner as to isolate the machine or equipment from the energy source(s): a) On or about August 29, 2024, at Kiln 2 area, the valve for main air line was not turned off or shut down while employees were disconnecting the compressor's hose from the main air line.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at Oxbow Calcining LLC
View Oxbow Calcining LLC's full OSHA safety record →
More inspections in this industry (NAICS 324199)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347734741.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.