Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: ANCHOR GLASS CONTAINER CORPORATION

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of ANCHOR GLASS CONTAINER CORPORATION in 151 EAST MCCANNS BLVD, ELMIRA HEIGHTS, NY 14903 (NAICS 327213). OSHA activity number 347735649.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Anchor Glass Container Corporation — free Get an email when a new federal OSHA severe-injury report for Anchor Glass Container Corporation is published. One employer, no account, unsubscribe in one click.
Site address
151 EAST MCCANNS BLVD
City
ELMIRA HEIGHTS
State
NY
ZIP
14903
Mailing
151 EAST MCCANNS BLVD, ELMIRA HEIGHTS, NY 14903
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
327213
Employees
220
Ownership type
A

11 citations on file for this inspection.

1910.27 A

Serious Gravity 5 1 instance 3 exposed
Issued
Jan 31, 2025
Abate by
May 28, 2025
Penalty
Initial $10,403 · Current $5,201 Reduced
29 CFR 1910.27(a): The employer did not ensure that scaffolds used in general industry meet the requirements in 29 CFR part 1926, subpart L (Scaffolds).  (a) Anchor Glass Container Corporation, 151 East McCanns Boulevard, Elmira Heights, NY 14903, on or about 8/30/2024- Employees working from scaffolding were assigned to patch a hole on a batch bin in the Coal Building. The scaffolding did not meet the requirements of 29 CFR �� 1926.45l(f)(3) and (f)(15), in that a competent person did not complete an inspection for visible defects before the work shift and a stepladder was used on the scaffold to increase the working height of employees without providing for additional fall protection.  Abatement certification is required.
Recent events (3)
  • — F (S) $5201
  • — C (S) $10403
  • — Z (S) $10403

1910.134 F02

Other-than-serious Gravity 5 1 instance 1 exposed
Issued
Jan 31, 2025
Abate by
May 28, 2025
Penalty
Initial $10,403 · Current $0 Reduced

Hazardous substances S103

29 CFR 1910.134(f)(2): Employee(s) using tight-fitting facepiece respirators were not fit tested prior to initial use of the respirator:  a) Anchor Glass Container Corporation, 151 East McCanns Blvd, Elmira Heights, NY 14903, on or about 8/19/2024; Maintenance employees were required to wear tight-fitting respirators when completing activities that create dust and when working in the batch house and the employer did not complete fit tests with all maintenance employees.  Abatement certification is required
Recent events (3)
  • — F (O) $0
  • — C (S) $10403
  • — Z (S) $10403

1910.134 K03

Other-than-serious Gravity 5 1 instance 1 exposed
Issued
Jan 31, 2025
Abate by
May 28, 2025
Penalty
Initial $0 · Current $0
29 CFR 1910.134(k)(3): Employees were not provided with training before using respiratory protection.   a) Anchor Glass Container Corporation, 151 East McCanns Blvd, Elmira Heights, NY 14903, on or about 8/19/2024; Maintenance employees were required to wear tight-fitting respirators when completing activities that create dust and when working in the batch house and the employer did not complete comprehensive training at least annually.  Abatement certification is required.
Recent events (3)
  • — F (O) $0
  • — C (S) $0
  • — Z (S) $0

1910.134 L02

Deleted Serious Gravity 5 1 instance 2 exposed
Issued
Jan 31, 2025
Abate by
Feb 27, 2025
Penalty
Initial $0 · Current $0
29 CFR 1910.134(l)(2): The employer did not regularly consult employees required to use respirators to assess the employees' views on program effectiveness and to identify any problems:  a) Anchor Glass Container Corporation, 151 East McCanns Blvd, Elmira Heights, NY 14903, on or about 9/5/2024; The employer did not consult with employees required to use respirators to evaluate the program's effectiveness and identify problems.   Abatement certification is required.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

1910.146 C07 III

Other-than-serious Gravity 10 1 instance 3 exposed
Issued
Jan 31, 2025
Penalty
Initial $16,550 · Current $1,461 Reduced
29 CFR  1910.146(c)(7)(iii):The employer's written certification determining that all hazards in a permit space had been eliminated was not made available to each employee entering the permit space:  a) Anchor Glass Container Corporation, 151 East McCanns Blvd, Elmira Heights, NY 14903, on or about 8/30/2024; The employer completed a written reclassification form and directed employees to enter into a permit required confined space (coal silo). The employer did not make the written certification available to each employee entering the permit space.
Recent events (3)
  • — F (O) $1461
  • — C (S) $16550
  • — Z (S) $16550

1910.146 E01

Deleted Serious Gravity 5 1 instance 3 exposed
Issued
Jan 31, 2025
Abate by
Mar 20, 2025
Penalty
Initial $0 · Current $0
29 CFR 1910.146(e)(1): Before entry was authorized, the employer did not document the completion of measures required by 29 CFR 1910.146(d)(3) by preparing an entry permit:  a) Anchor Glass Container Corporation, 151 East McCanns Blvd, Elmira Heights, NY 14903, on or about 8/30/2024; The employer directed employees to complete maintenance tasks in a permit-required confined space, coal silo, and did not complete an entry permit prior to employees entering the space.  Note:  Appendix D to 29 CFR 1910.146 presents examples of permits whose elements are considered to comply with these requirements.  Abatement certification is required.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

1910.146 D09

Deleted Serious Gravity 5 1 instance 3 exposed
Issued
Jan 31, 2025
Abate by
Feb 27, 2025
Penalty
Initial $13,005 · Current $0 Reduced
29 CFR  1910.146(d)(9):The employer did not develop and implement procedures for summoning rescue and emergency services, for rescuing entrants from permit spaces, for providing necessary emergency services to rescued employees, and/or for preventing unauthorized entry.  a) Anchor Glass Container Corporation, 151 East McCanns Blvd, Elmira Heights, NY 14903, on or about 8/30/2024; The employer directed employees to complete maintenance tasks in a permit-required confined space, coal silo, and did not develop or implement procedures for rescuing entrants from the permit space.  Abatement certification is required.
Recent events (3)
  • — F (S) $0
  • — C (S) $13005
  • — Z (S) $13005

1910.1053 D01

Other-than-serious Gravity 5 1 instance 3 exposed
Issued
Jan 31, 2025
Abate by
May 28, 2025
Penalty
Initial $10,403 · Current $3,000 Reduced

Hazardous substances 9000

29 CFR 1910.1053(d)(1): The employer did not assess the exposure of each employee who was or may reasonably be expected to be exposed to respirable crystalline silica at or above the action level in accordance with either the performance option in paragraph (d)(2) or the scheduled monitoring option in paragraph (d)(3) of this section:  a) Anchor Glass Container Corporation, 151 East McCanns Blvd, Elmira Heights, NY 14903, on or about 8/30/2024; Employees were assigned to complete work in the coal silo with airborne batch material, which contains respirable crystalline silica, and the employer did not assess the exposure of the employees.  Abatement certification is required.
Recent events (3)
  • — F (O) $3000
  • — C (S) $10403
  • — Z (S) $10403

1910.1053 J01

Other-than-serious Gravity 5 1 instance 3 exposed
Issued
Jan 31, 2025
Abate by
May 28, 2025
Penalty
Initial $0 · Current $0

Hazardous substances 9000

29 CFR  1910.1053(j)(1):The employer did not include respirable crystalline silica in the program established to comply with the hazard communication standard (HCS) (29 CFR 1910.1200):  a) Anchor Glass Container Corporation, 151 East McCanns Blvd, Elmira Heights, NY 14903, on or about 8/30/2024; Employees were assigned to complete work in the coal silo with airborne batch material, which contains respirable crystalline silica, and the employer did not include respirable crystalline silica in their hazard communication program.  Abatement certification is required.
Recent events (3)
  • — F (O) $0
  • — C (S) $0
  • — Z (S) $0

1910.1053 J03 I B

Deleted Serious Gravity 5 1 instance 3 exposed
Issued
Jan 31, 2025
Abate by
Feb 27, 2025
Penalty
Initial $0 · Current $0

Hazardous substances 9000

29 CFR 1910.1053(j)(3)(i)(B): The employer did not ensure that each employee covered by this section could demonstrate knowledge and understanding of specific tasks in the workplace that could result in exposure to respirable crystalline silica:  a) Anchor Glass Container Corporation, 151 East McCanns Blvd, Elmira Heights, NY 14903, on or about 8/30/2024; Employees were assigned to complete work in the coal silo with airborne batch material, which contains respirable crystalline silica, and the employer did not educate the employees of the potential for exposure to silica dust in the coal silo or its associated hazards.  Abatement certification is required.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

1910.146 G01

Deleted Repeat Gravity 5 1 instance 2 exposed
Issued
Jan 31, 2025
Abate by
Feb 27, 2025
Penalty
Initial $65,027 · Current $0 Reduced
29 CFR 1910.146(g)(1): The employer did not provide training so that all employees whose work was regulated by 29 CFR 1910.146 (permit required confined spaces) acquired the understanding, knowledge, and skills necessary for the safe performance of the duties assigned under 29 CFR 1910.146:  a) Anchor Glass Container Corporation, 151 East McCanns Blvd, Elmira Heights, NY 14903, on or about 8/30/2024; Employees were working around and entering permit required confined spaces in the facility. The employer had not provided employees with training on the hazards associated with permit required confined spaces and the requirement not to enter permit required confined spaces without proper procedures and authorization.   Anchor Glass Container Corporation, 151 East McCanns Blvd, Elmira Heights, NY 14903 was previously citated for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1910.146(g)(1), which was contained in OSHA inspection number 1575610, citation 1 item number 4 and affirmed as final order on 8/12/2022.
Recent events (3)
  • — F (R) $0
  • — C (R) $65027
  • — Z (R) $65027

View Anchor Glass Container Corporation's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347735649.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.