Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: GEORGE CARPENTRY AND REMODELING CORP.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of GEORGE CARPENTRY AND REMODELING CORP. in 111 FREIGHT STREET, PAWTUCKET, RI 02860 (NAICS 238160). OSHA activity number 347743106.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch George Carpentry and Remodeling Corp. — free Get an email when a new federal OSHA severe-injury report for George Carpentry and Remodeling Corp. is published. One employer, no account, unsubscribe in one click.
Site address
111 FREIGHT STREET
City
PAWTUCKET
State
RI
ZIP
02860
Mailing
358 COFFIN AVENUE, NEW BEDFORD, MA 02746
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
7
Ownership type
A

5 citations on file for this inspection.

1926.451 C02

Serious Gravity 10 2 instances 5 exposed
Issued
Oct 16, 2024
Penalty
Initial $4,839 · Current $4,839
29 CFR  1926.451(c)(2): Supported scaffold poles, legs, posts, frames, or uprights did not bear on base plates and mud sills or other adequate firm foundation.   (a) Worksite: On or about 09-10-2024, employees were exposed to fall hazards while working from a 24-foot Alum-a-pole pumpjack scaffold that was not set on base plates and mud sills or other adequate firm foundation during roof shingle activities at a height of approximately 15 feet 3 inches above the lower level.
Recent events (1)
  • — Z (S) $4839

1926.451 G01

Serious Gravity 10 1 instance 5 exposed
Issued
Oct 16, 2024
Penalty
Initial $0 · Current $0
29 CFR  1926.451(g)(1): Each employee on a scaffold more than 10 feet above a lower level was not protected from falling to that lower level.  (a) Worksite - front of the building:  On or about 09-10-2024, employees were exposed to fall hazards while working from a pump jack scaffold system approximately 15 feet 3 inches above the lower level, without any means of fall protection.
Recent events (1)
  • — Z (S) $0

1926.452 J02

Serious Gravity 10 2 instances 5 exposed
Issued
Oct 16, 2024
Penalty
Initial $0 · Current $0
29 CFR  1926.452(j)(2): Poles were not secured to the structure by rigid triangular bracing or equivalent at the bottom, top, and other points as necessary.   (a) Worksite: On or about 09-10-2024, employees were exposed to fall hazards while working from a 24-foot Alum-a-pole pumpjack scaffold that was not secured to the structure at the bottom to prevent the scaffold from slipping outward away from the structure, during roof shingle activities at a height of approximately 15 feet 3 inches above the lower level.
Recent events (1)
  • — Z (S) $0

1926.501 B13

Serious Gravity 10 1 instance 1 exposed
Issued
Oct 16, 2024
Penalty
Initial $4,839 · Current $4,839
29 CFR  1926.501(b)(13): Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employees provided with an alternative fall protection measure under another provision of paragraph 1926.501(b).  (a) Worksite: On or about 09-10-2024, employees were exposed to fall hazards while removing and installing roof shingles at a height of approximately 25 feet above the lower level without any means of fall protection.
Recent events (1)
  • — Z (S) $4839

1926.1053 B10

Serious Gravity 5 1 instance 1 exposed
Issued
Oct 16, 2024
Penalty
Initial $3,457 · Current $3,457
29 CFR  1926.1053(b)(10): The tops of a non-self-supporting ladder were not placed with the two rails supported equally.   (a) Worksite: On or about 09-10-2024, employees were exposed to fall hazards while removing and replacing shingles at a height of approximately 17 feet above the lower level on a residential roof while utilizing a 32-foot Werner extension ladder with its two rails set unequally on the sloped portion of a pitched roof, causing it to be unstable.
Recent events (1)
  • — Z (S) $3457

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347743106.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.