ROCHESTER, NY —
OSHA Inspection: CANNON INDUSTRIES, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of CANNON INDUSTRIES, INC. in 525 LEE ROAD, ROCHESTER, NY 14606 (NAICS 332322). OSHA activity number 347745473.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- CANNON INDUSTRIES, INC.
- Site address
- 525 LEE ROAD
- City
- ROCHESTER
- State
- NY
- ZIP
- 14606
- Mailing
- 525 LEE ROAD, ROCHESTER, NY 14606
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332322
- Employees
- 75
- Ownership type
- A
Citations
4 citations on file for this inspection.
1910.37 A03
- Issued
- Sep 23, 2024
- Abate by
- Nov 25, 2024
- Penalty
- Initial $5,288 · Current $2,500 Reduced
General-duty citation text
29 CFR 1910.37(a)(3): Exit route(s) were not kept free and unobstructed: a) On or about 09/10/2024, in the storage rack area; employees were exposed to fire hazards when exit routes were blocked with pallets of materials that spread a cross the aisleway and could not be easily moved without a powered industrial vehicle. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $2500
- — Z (S) $5288
1910.147 C04 I
- Issued
- Sep 23, 2024
- Abate by
- Jan 24, 2025
- Penalty
- Initial $7,052 · Current $4,000 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: a) On or about 09/10/2024, throughout the establishment; Employees were exposed to caught in hazards when Lockout/Tagout procedures were not developed, documented, and utilized for the purpose of controlling hazardous energy when employees performed servicing and maintenance such as, but not limited to, changing tools on Amada RG 80 ton Press Brake. b) On or about 09/10/2024, throughout the establishment; Employees were exposed to caught in hazards when Lockout/Tagout procedures were not developed, documented, and utilized for the purpose of controlling hazardous energy when employees performed servicing and maintenance such as, but not limited to, changing dies on Federal 150 ton Press. ABATEMENT DOCUMENTATION REQUIRED
Recent events (2)
- — I (S) $4000
- — Z (S) $7052
1910.147 C06 I
- Issued
- Sep 23, 2024
- Abate by
- Jan 24, 2025
- Penalty
- Initial $7,052 · Current $4,000 Reduced
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: a) On or about 09/10/2024, throughout the establishment; employer did not conduct periodic inspections of the Lockout/Tagout procedures at least annually to verify each procedure was adequate and being properly used by employees responsible for locking out machines during servicing or maintenance, such as but not limited to; Amada Brake Presses; BHFE M2 2204, HRB1003, and HRB1303, Federal 150 ton Press, Mazak Laser Serial #190282. ABATEMENT DOCUMENTATION REQUIRED
Recent events (2)
- — I (S) $4000
- — Z (S) $7052
1910.303 G01
- Issued
- Sep 23, 2024
- Abate by
- Nov 25, 2024
- Penalty
- Initial $990 · Current $0 Reduced
General-duty citation text
29 CFR 1910.303(g)(1): Sufficient access and working space was not provided and maintained about all electric equipment (operating at 600 volts, nominal, or less to ground) to permit ready and safe operation and maintenance of such equipment: a) On or about 09/10/2024, throughout the establishment; Where employees were exposed to electrical hazards when access to the approximately 9 breaker boxes, which fed power to different equipment such as but not limited to; roll-up gate, and EDM machines, were blocked by the storage of materials. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (O) $0
- — Z (O) $990
More inspections at Cannon Industries, INC.