OSHA Inspection: CONE AG, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of CONE AG, INC. in 2000 SOUTH 4TH STREET, ONIDA, SD 57564 (NAICS 115112). OSHA activity number 347748824.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Cone AG, INC. — free Get an email when a new federal OSHA severe-injury report for Cone AG, INC. is published. One employer, no account, unsubscribe in one click.
Establishment
CONE AG, INC.
Site address
2000 SOUTH 4TH STREET
City
ONIDA
State
SD
ZIP
57564
Mailing
2400 EAST DAKOTA AVENUE, PIERRE, SD 57501
Inspection type
Planned (H)
Scope
Records only (C)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
115112
Employees
9
Ownership type
A

4 citations on file for this inspection.

1910.219 E03 I

Serious Gravity 5 1 instance 9 exposed
Issued
Oct 22, 2024
Abate by
Nov 22, 2024
Penalty
Initial $5,485 · Current $3,291 Reduced
29 CFR  1910.219(e)(3)(i): Vertical or inclined belts were not enclosed by guards conforming to the requirements specified at 29 CFR 1910.219(m) and (o):  (a)Cone AG, Inc. at 2000 South 4th Street, Onida , SD 57564: On or about and at times prior to September 11, 2024, the employer did not ensure that adequate guarding was in place on the Dry Fertilizer Hopper within the dry fertilizer building.  This condition exposed employees to caught-in and amputation hazards.
Recent events (2)
  • — I (S) $3291
  • — Z (S) $5485

1910.303 G01 I A

Serious Gravity 1 1 instance 9 exposed
Issued
Oct 22, 2024
Abate by
Nov 22, 2024
Penalty
Initial $4,113 · Current $2,468 Reduced
29 CFR  1910.303(g)(1)(i)(A): For electric equipment operating at 600 volts, nominal, or less to ground, and likely to require examination, adjustment, servicing, or maintenance while energized, the depth of the working space in the direction of access to live parts (as measured from the live parts where they were exposed or from the enclosure front or opening where they were enclosed) was less than indicated in Table S-1 of Subpart S of Part 1910:   (a)Cone AG, Inc. at 2000 South 4th Street, Onida , SD 57564: On or about and at times prior to September 11, 2024, the employer did not ensure unimpeded access to an electrical panel in the Seed Storage Building on the northwest corner of the building.  This condition exposed employees to potential shock and electrocution hazards related to the inability to disable power during an emergency.
Recent events (2)
  • — I (S) $2467.8
  • — Z (S) $4113

1910.25 B03

Other-than-serious 2 instances 9 exposed
Issued
Oct 22, 2024
Abate by
Nov 22, 2024
Penalty
Initial $0 · Current $0
29 CFR 1910.25(b)(3): The employer did not ensure that stairs have uniform riser heights and tread depths between landings.  (a)Cone AG, Inc. at 2000 South 4th Street, Onida , SD 57564: On or about and at times prior to September 11, 2024, the employer did not ensure that brick systems utilized as stairs to enter and egress from the berm of the Liquid Fertilizer area had uniform riser heights and tread depths between landings.  This condition exposed employees to slip, trip and fall hazards associated with non-uniform walking/working surfaces.  (b)Cone AG, Inc. at 2000 South 4th Street, Onida , SD 57564: On or about and at times prior to September 11, 2024, the employer did not ensure that the homemade wood stair system utilized to enter and egress from the control room to the berm of the Liquid Fertilizer area had uniform riser heights and tread depths between landings.  This condition exposed employees to slip, trip and fall hazards associated with non-uniform walking/working surfaces.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.146 C02

Other-than-serious 1 instance 9 exposed
Issued
Oct 22, 2024
Abate by
Nov 22, 2024
Penalty
Initial $0 · Current $0
29 CFR  1910.146(c)(2):The employer did not inform exposed employees, by posting danger signs or by any other equally effective means, of the existence and location of and the danger posed by the permit spaces by sign reading DANGER-PERMIT-REQUIRED CONFINED SPACE, DO NOT ENTER or using other similar language which would satisfy the requirement for a sign:  (a)Cone AG, Inc. at 2000 South 4th Street, Onida , SD 57564: On or about and at times prior to September 11, 2024, the employer did not ensure that signage or other effective means were used to warn employees of the danger posed by accessible permit required confined spaces, to include but not limited, to the Liquid Fertilizer tank area.  This condition exposed employees to hazards associated with uninformed entry into a confined space, including asphyxiation.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347748824.