Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: PARAGON PLASTICS LLC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of PARAGON PLASTICS LLC in 1401 ARMSTRONG DRIVE, TITUSVILLE, FL 32780 (NAICS 424610). OSHA activity number 347751968.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Paragon Plastics LLC — free Get an email when a new federal OSHA severe-injury report for Paragon Plastics LLC is published. One employer, no account, unsubscribe in one click.
Site address
1401 ARMSTRONG DRIVE
City
TITUSVILLE
State
FL
ZIP
32780
Mailing
1401 ARMSTRONG DRIVE, TITUSVILLE, FL 32780
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
424610
Employees
59
Ownership type
A

2 citations on file for this inspection.

1910.212 A03 II

Serious Gravity 10 1 instance 2 exposed
Issued
Nov 19, 2024
Abate by
Feb 7, 2025
Penalty
Initial $11,292 · Current $6,775 Reduced
29 CFR  1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s):  a. On or about September 11, 2024 at 1401 Armstrong Drive, Titusville, FL 32780, employees were exposed to amputation hazards in that the guard   of the Rockwell Band Saw, Model 28-3XO, Serial Number 1529182, was not properly adjusted while trimming excess molding material.
Recent events (2)
  • — I (S) $6775.2
  • — Z (S) $11292

1910.242 B

Serious Gravity 5 3 instances 3 exposed
Issued
Nov 19, 2024
Abate by
Feb 7, 2025
Penalty
Initial $9,680 · Current $5,808 Reduced
29 CFR  1910.242(b):Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.:  a) On or about September 11, 2024, at 1401 Armstrong Drive, Titusville, FL 32780, the employer allowed the use of 107 psi air to clean and blow debris from trimming materials operation, exposing employees to struck-by and embolism hazards.
Recent events (2)
  • — I (S) $5808
  • — Z (S) $9680

View Paragon Plastics LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347751968.