TITUSVILLE, FL —
OSHA Inspection: PARAGON PLASTICS LLC
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of PARAGON PLASTICS LLC in 1401 ARMSTRONG DRIVE, TITUSVILLE, FL 32780 (NAICS 424610). OSHA activity number 347751968.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- PARAGON PLASTICS LLC
- Site address
- 1401 ARMSTRONG DRIVE
- City
- TITUSVILLE
- State
- FL
- ZIP
- 32780
- Mailing
- 1401 ARMSTRONG DRIVE, TITUSVILLE, FL 32780
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 424610
- Employees
- 59
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.212 A03 II
- Issued
- Nov 19, 2024
- Abate by
- Feb 7, 2025
- Penalty
- Initial $11,292 · Current $6,775 Reduced
General-duty citation text
29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s): a. On or about September 11, 2024 at 1401 Armstrong Drive, Titusville, FL 32780, employees were exposed to amputation hazards in that the guard of the Rockwell Band Saw, Model 28-3XO, Serial Number 1529182, was not properly adjusted while trimming excess molding material.
Recent events (2)
- — I (S) $6775.2
- — Z (S) $11292
1910.242 B
- Issued
- Nov 19, 2024
- Abate by
- Feb 7, 2025
- Penalty
- Initial $9,680 · Current $5,808 Reduced
General-duty citation text
29 CFR 1910.242(b):Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.: a) On or about September 11, 2024, at 1401 Armstrong Drive, Titusville, FL 32780, the employer allowed the use of 107 psi air to clean and blow debris from trimming materials operation, exposing employees to struck-by and embolism hazards.
Recent events (2)
- — I (S) $5808
- — Z (S) $9680
More inspections at Paragon Plastics LLC
View Paragon Plastics LLC's full OSHA safety record →
More inspections in this industry (NAICS 424610)
More inspections in FL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347751968.