OSHA Inspection: TWIN OAK CONSTRUCTION AND FRAMING

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of TWIN OAK CONSTRUCTION AND FRAMING in 9703 POTRANCO, SAN ANTONIO, TX 78245 (NAICS 238130). OSHA activity number 347754228.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Twin OAK Construction and Framing — free Get an email when a new federal OSHA severe-injury report for Twin OAK Construction and Framing is published. One employer, no account, unsubscribe in one click.
Site address
9703 POTRANCO
City
SAN ANTONIO
State
TX
ZIP
78245
Mailing
21750 HARDY OAK BLVD, SAN ANTONIO, TX 78258
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Last modified
Data loaded
NAICS code
238130
Employees
12
Ownership type
A

2 citations on file for this inspection.

1926.453 B02 IV

Serious Gravity 5 1 instance 2 exposed
Issued
Oct 16, 2024
Penalty
Initial $5,531 · Current $2,800 Reduced
29 CFR  1926.453(b)(2)(iv):Employee(s) working in an aerial lift were not standing firmly on the floor of the basket:  On or about September 10, 2024, and at times prior thereto, employees stood on the mid-rail of an elevated JLG aerial lift while installing side panel concrete to a commercial building.
Recent events (2)
  • — I (S) $2800
  • — Z (S) $5531

1926.453 B02 V

Serious Gravity 5 1 instance 2 exposed
Issued
Oct 16, 2024
Penalty
Initial $5,531 · Current $2,800 Reduced
29 CFR  1926.453(b)(2)(v):A body belt was not worn and/or a lanyard was not attached to the boom or basket when working from an aerial lift :Note:  As of January 1, 1998, subpart M of this part (1926.502(d)) provides that body belts are not acceptable as part of a personal fall arrest system.  The use of a body belt in a tethering system or in a restraint system is acceptable and is regulated:   On or about September 10, 2024, and at times prior thereto, employees installing side panel concrete to a commercial building were not tethered to the JLG aerial lift they were working in while it was in an elevated position.