Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,214Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: MANUEL FIERRO

Federal Agency inspection · Safety discipline

On , OSHA opened a federal Agency safety inspection of MANUEL FIERRO in 12902 CONNELL ST, OVERLAND PARK, KS 66212 (NAICS 561730). OSHA activity number 347754269.

Watch Manuel Fierro — free Get an email when a new federal OSHA severe-injury report for Manuel Fierro is published. One employer, no account, unsubscribe in one click.
Establishment
MANUEL FIERRO
Site address
12902 CONNELL ST
City
OVERLAND PARK
State
KS
ZIP
66212
Mailing
5403 MEADOWLARK DRIVE, SHAWNEE, KS 66226
Inspection type
Federal Agency (M)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Last modified
Data loaded
NAICS code
561730
Employees
3
Ownership type
A

5 citations on file for this inspection.

1910.332 B01

Serious Gravity 10 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $4965.00 · Current $4965.00
29 CFR  1910.332(b)(1): Employees were not trained in and familiar with the safety-related work practices required by 1910.331 through 1910.335 that pertained to their respective job assignments:    On or about September 13, 2024, employees were exposed to electrical hazards when assigned to trim trees near energized overhead power lines. The employer did not train employees and ensure they were familiar with safety-related work practices addressing electrical hazards related to tree trimming near unprotected energized 7200 V overhead electrical power distribution line.
Recent events (1)
  • — Z (S) $4965

1910.333 C03

Serious Gravity 10 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $4965.00 · Current $4965.00
29 CFR  1910.333(c)(3): When work was to be performed near overhead lines, the lines were not de-energized and grounded, nor were other protective measures provided before work was started.  Where lines are to be de-energized, arrangements were not made with the person or organization that operates or controls the electric circuits involved to de-energize and ground them.  On or about September 13, 2024, employees were exposed to electrical hazards when trimming a tree near energized unguarded overhead power lines. The employer did not arrange with the power distributor for the overhead power lines to be de-energized and grounded, nor did the employer institute other protective measures before tree trimming work started. An employee trimmed with a manual aluminum pole saw 9 feet, 9 inches from an energized unguarded 7200 volts overhead power distribution line.
Recent events (1)
  • — Z (S) $4965

1910.333 C03 I A 1

Serious Gravity 10 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.333(c)(3)(i)(A)(1): When an unqualified person was working in an elevated position near overhead lines with voltages to ground rated at 50 kV or below, the location was not such that the person and the longest conductive object he or she could contact came closer than 10 ft. (305 cm) to any unguarded, energized overhead line:  On or about September 13, 2024, an unqualified employee was exposed to electrical hazards posed by a 7200-volt overhead power distribution line while tree trimming. The employer failed to ensure the employee elevated in a tree was located such that neither the employee nor their long conductive pole saw would contact or come closer than 10 feet from the unguarded energized overhead line or tree limbs contacting the power line. The elevated employee used a pole saw extended greater than 20 feet while he was approximately 9 feet, 9 inches from the overhead line when they contacted an energized limb or power line.
Recent events (1)
  • — Z (S) $0

1910.335 A01 I

Serious Gravity 10 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $4965.00 · Current $4965.00
29 CFR  1910.335(a)(1)(i): Employees working in areas where there were potential electrical hazards were not provided with electrical protective equipment that was appropriate for the specific parts of the body that needed to be protected and for the work being performed:  On or about September 13, 2024, employees were exposed to electrical hazards when conducting tree trimming work. The employer did not provide employees with electrical protective equipment including but not limited to insulated gloves for hands when trimming trees near an unprotected energized 7200 volts overhead electrical power distribution line.
Recent events (1)
  • — Z (S) $4965

1910.335 A02 I

Serious Gravity 10 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.335(a)(2)(i): When working near exposed energized conductors or circuit parts, each employee did not use insulated tools or handling equipment when the tools or handling equipment might have made contact with such conductors or parts:  On or about September 13, 2024,  an employee was performing tree-trimming operations near overhead power lines with a non-insulated saw, exposing him to electrical hazards.
Recent events (1)
  • — Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347754269.