JBER, AK —
OSHA Inspection: 176TH WG/SE
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of 176TH WG/SE in 17508 AIRLIFTER DRIVE -HANGER 21, JBER, AK 99506 (NAICS 928110). OSHA activity number 347759565.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- 176TH WG/SE
- Site address
- 17508 AIRLIFTER DRIVE -HANGER 21
- City
- JBER
- State
- AK
- ZIP
- 99506
- Mailing
- 7252 12TH STREET, JBER, AK 99506
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 928110
- Employees
- 25
- Ownership type
- D
Citations
2 citations on file for this inspection.
1926.502 D15 I
- Issued
- Oct 2, 2024
- Abate by
- Oct 29, 2024
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.502(d)(15)(i): Anchorages used for attachment of personal fall arrest equipment were not designed, installed, and used as part of a complete personal fall arrest system which maintains a safety factor of at least two: a) Hanger 21: On or about May 10, 2024, the fall protection system trolly had inadequate bumper guards and fell of the system while 3rd MXS employee(s) were conducting assigned work and the system was not removed from service, exposing employees to struck by and fall hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.502 D21
- Issued
- Oct 2, 2024
- Abate by
- Oct 29, 2024
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.502(d)(21): Personal fall arrest systems were not inspected prior to each use for wear, damage, and other deterioration, and/or defective components were not removed from service: a) Hanger 21: On or about May 10, 2024, the fall protection system was not inspected prior to work assigned to 3rd MXS employee(s) and neither was the system removed from service, exposing employees to struck by and fall hazards.