RENSSELAER, NY —
OSHA Inspection: DFA DAIRY BRANDS FLUID, LLC
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of DFA DAIRY BRANDS FLUID, LLC in 504 THIRD AVENUE EXT., RENSSELAER, NY 12144 (NAICS 311511). OSHA activity number 347760100.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- DFA DAIRY BRANDS FLUID, LLC
- Site address
- 504 THIRD AVENUE EXT.
- City
- RENSSELAER
- State
- NY
- ZIP
- 12144
- Mailing
- 504 THIRD AVENUE EXT., RENSSELAER, NY 12144
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Last modified
- Data loaded
Establishment context
- NAICS code
- 311511
- Employees
- 206
- Ownership type
- A
Citations
6 citations on file for this inspection.
1910.147 C04 I
- Issued
- Jan 23, 2025
- Abate by
- Jan 29, 2025
- Penalty
- Initial $9,457 · Current $5,674 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: a) Filler Machine 2 Area - On or about August 12, 2024, an employee was exposed to electric shock hazards when performing the servicing and maintenance task of greasing on a Filler 2 machine (Federal MFG. CO, Federal Filler #2 - 1900GWSS6/268L728, Energy sources - electrical and plant air) due to not performing Lockout/Tagout.
Recent events (2)
- — I (O) $5674.2
- — Z (S) $9457
1910.147 C06 I
- Issued
- Jan 23, 2025
- Abate by
- Jan 29, 2025
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: a) Facility - On or about August 12, 2024, an employee was exposed to electric shock hazards when performing the servicing and maintenance task of greasing on a Filler 2 machine (Federal MFG. CO, Federal Filler #2 - 1900GWSS6/268L728, Energy sources - electrical and plant air) due to not performing Lockout/Tagout. The employer did not conduct a periodic inspection of the energy control procedure at least annually.
Recent events (2)
- — I (O) $0
- — Z (S) $0
1910.147 C07 III B
- Issued
- Jan 23, 2025
- Abate by
- Jan 29, 2025
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(7)(iii)(B): Additional retraining was not provided whenever the employer has reason to believe that there were deviations from or inadequacies in the employee's knowledge or use of the energy control procedures: a) Facility - On or about August 12, 2024, an employee was exposed to electric shock hazards when performing the servicing and maintenance task of greasing on Filler 2 machine (Federal MFG. CO, Federal Filler #2 - 1900GWSS6/268L728, Energy sources - electrical and plant air) due to not performing Lockout/Tagout. The employee was not re-trained on lockout/tagout after the employee did not perform lockout/tagout previously in an incident on July 16, 2024, on the hydraulic ram that actuates a gate brake in the cooler. The employer would have reason to believe that there were deviations in the employee's knowledge or use of the energy control procedures due to the incident on July 16, 2024, due to the employee not performing Lockout/Tagout.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.219 C02 I
- Issued
- Jan 23, 2025
- Abate by
- Jan 29, 2025
- Penalty
- Initial $9,457 · Current $5,674 Reduced
General-duty citation text
29 CFR 1910.219(c)(2)(i):All exposed part(s) of horizontal shafting seven (7) feet or less from floor or working platform were not protected by stationary casing(s) enclosing shafting completely or by trough(s) enclosing sides and top or sides and bottom of shafting: a) Filler Machine 2 area by Control Station - On or about September 17, an employee was exposed to caught-in hazards due to working near an unguarded shaft end. b) Filler Machine 2 area by Ladder - On or about September 17, 2024, an employee was exposed to caught-in hazards due to working near an unguarded shaft end. c) Merge Area by the Hydraulic Pump/Merge Panel - On or about September 17, 2024, an employee was exposed to caught-in hazards due to working near an unguarded shaft end.
Recent events (2)
- — I (O) $5674.2
- — Z (S) $9457
1910.1200 F06 II
- Issued
- Oct 7, 2024
- Abate by
- Oct 11, 2024
- Penalty
- Initial $6,913 · Current $4,493 Reduced
General-duty citation text
29 CFR 1910.1200(f)(6)(ii): Except as provided in 29 CFR 1910.1200(f)(7) and 29 CFR 1910.1200(f)(8), the employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the product identifier and words, pictures, symbols, or combination thereof, which provide at least general information regarding the hazards of the chemicals and which, in conjunction with the other information immediately available to employees under the hazard communication program, would provide employees with the specific information regarding the physical and health hazards of the hazardous chemical: a) Facility - On or about April 14, 2024, a maintenance technician employee was exposed to the release of small traces of anhydrous ammonia due to transferring an oil mixture (mixture of mostly water, oil - Frick #3, and small traces of Anhydrous Ammonia) from a brown bucket labeled 'Maintenance Only Used Oil' into a used oil drum. The labeling on the brown bucket did not include information regarding Anhydrous Ammonia. b) Facility - On or about April 28, 2024, a maintenance technician employee was exposed to the release of small traces of anhydrous ammonia due to transferring an oil mixture (mixture of mostly water, oil - Frick #3, and small traces of Anhydrous Ammonia) from a brown bucket into another brown bucket. The labeling on the brown buckets consisted of the labeling 'Maintenance Only Used Oil' and did not include information regarding Anhydrous Ammonia.
Recent events (2)
- — I (S) $4493.47
- — Z (S) $6913
1910.1200 H01
- Issued
- Oct 7, 2024
- Abate by
- Oct 11, 2024
- Penalty
- Initial $6,913 · Current $4,493 Reduced
General-duty citation text
29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area: a) Facility - On or about April 14, 2024, a maintenance technician employee was exposed to the release of small traces of anhydrous ammonia due to transferring an oil mixture (mixture of mostly water, oil - Frick #3, and small traces of Anhydrous Ammonia) from a brown bucket labeled 'Maintenance Only Used Oil' into a used oil drum. The labeling on the brown bucket did not include information regarding Anhydrous Ammonia. The employee was not provided effective information and training on the hazardous chemicals in their work area. b) Facility - On or about April 28, 2024, a maintenance technician employee was exposed to the release of small traces of anhydrous ammonia due to transferring an oil mixture (mixture of mostly water, oil - Frick #3, and small traces of Anhydrous Ammonia) from a brown bucket into another brown bucket. The labeling on the brown buckets consisted of the labeling 'Maintenance Only Used Oil' and did not include information regarding Anhydrous Ammonia. The employee was not provided effective information and training on the hazardous chemicals in their work area.
Recent events (2)
- — I (O) $4493.45
- — Z (S) $6913
More inspections at DFA Dairy Brands Fluid, LLC
View DFA Dairy Brands Fluid, LLC's full OSHA safety record →
More inspections in this industry (NAICS 311511)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347760100.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.