OSHA Inspection: U.S. POSTAL SERVICE- PROCESSING & DISTRIBUTION CENTER

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of U.S. POSTAL SERVICE- PROCESSING & DISTRIBUTION CENTER in 100 SOUTH 1ST STREET, MINNEAPOLIS, MN 55401 (NAICS 491110). OSHA activity number 347767287.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch U.S. Postal Service- Processing & Distribution Center — free Get an email when a new federal OSHA severe-injury report for U.S. Postal Service- Processing & Distribution Center is published. One employer, no account, unsubscribe in one click.
Site address
100 SOUTH 1ST STREET
City
MINNEAPOLIS
State
MN
ZIP
55401
Mailing
100 SOUTH 1ST STREET, MINNEAPOLIS, MN 55401
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
491110
Employees
788
Ownership type
A

4 citations on file for this inspection.

1910.29 B13 I

Other-than-serious Gravity 5 1 instance 13 exposed
Issued
Nov 13, 2024
Abate by
Nov 27, 2024
Penalty
Initial $10,775 · Current $5,388 Reduced
29 CFR 1910.29(b)(13)(i): The guardrail system opening used around holes that serve as points of access (such as ladderways), did not have a self-closing gate that slides or swings away from the hole, and was equipped with a top rail and midrail or equivalent intermediate member that met the requirements in paragraph (b) of this section:   (a)  Floor 2 catwalk by the DPRC machines; On or about September 11, 2024, and dates prior, the employer failed to provide a self-closing gate at the fixed ladder access point to the catwalk.
Recent events (2)
  • — I (O) $5387.5
  • — Z (S) $10775

1910.147 C04 I

Deleted Serious Gravity 10 1 instance 1 exposed
Issued
Nov 13, 2024
Abate by
Nov 27, 2024
Penalty
Initial $15,082 · Current $0 Reduced
29 CFR 1910.147(c)(4)(i):  Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:   (a)  Floor 2; On or about September 8, 2024, the specific energy control procedure for the DPRC machine no. 2 was not utilized prior to performing service or maintenance activities on the upper call drum drive chain which resulted in the amputation of an employee's left index fingertip.
Recent events (2)
  • — I (S) $0
  • — Z (S) $15082

1910.147 C06 I

Serious Gravity 10 1 instance 13 exposed
Issued
Nov 13, 2024
Abate by
Jun 27, 2025
Penalty
Initial $0 · Current $7,541
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed:   (a) Floor 2; On or about September 8, 2024, and dates prior, the employer did not conduct periodic inspections of the DPRC machine no. 2 energy control procedure at least annually to ensure the procedure was accurate, employees were knowledgeable on the procedure, and the requirements of this standard were being followed.
Recent events (2)
  • — I (S) $7541
  • — Z (S) $0

1910.147 C07 III B

Serious Gravity 10 1 instance 1 exposed
Issued
Nov 13, 2024
Abate by
Jan 31, 2025
Penalty
Initial $0 · Current $0
1910.147(c)(7)(iii)(B) Additional retraining was not provided whenever a periodic inspection under 29 CFR 1910.147(c)(6) revealed that there were deviations from or inadequacies in the employee's knowledge or use of the energy control procedures:  (a) Floor 2; On or about September 8, 2024, energy control application steps such as, machine shutdown [(d)(2)], machine isolation [(d)(3)], and lockout/tagout device application [(d)(4)] were not in place prior to performing service or maintenance activities on the upper call drum drive chain which resulted in the amputation of an employee's left index fingertip.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347767287.