Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: LUIS ALBERTO-REYNA AVILA, AKA LUIS REYNA AVILA

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of LUIS ALBERTO-REYNA AVILA, AKA LUIS REYNA AVILA in 1018 LAFAYETTE ST., SCRANTON, PA 18504 (NAICS 238160). OSHA activity number 347770406.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Luis Alberto-Reyna Avila, AKA Luis Reyna Avila — free Get an email when a new federal OSHA severe-injury report for Luis Alberto-Reyna Avila, AKA Luis Reyna Avila is published. One employer, no account, unsubscribe in one click.
Site address
1018 LAFAYETTE ST.
City
SCRANTON
State
PA
ZIP
18504
Mailing
13 CHANDLER ST., WILKES BARRE, PA 18705
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Last modified
Data loaded
NAICS code
238160
Employees
10
Ownership type
A

12 citations on file for this inspection.

1910.1200 F06 II

Serious Gravity 5 1 instance 4 exposed
Issued
Mar 17, 2025
Abate by
Mar 27, 2025
Penalty
Initial $10,403 · Current $10,403
29 CFR 1910.1200(f)(6)(ii):  Except as provided in 29 CFR 1910.1200(f)(7) and 29 CFR 1910.1200(f)(8), the employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the product identifier and words, pictures, symbols, or combination thereof, which provide at least general information regarding the hazards of the chemicals and which, in conjunction with the other information immediately available to employees under the hazard communication program, would provide employees with the specific information regarding the physical and health hazards of the hazardous chemical: (Construction Reference: 1926.59):   Generator Area- On or about September 21, 2024, employees were exposed to fire hazards from the storage of gasoline in a kerosene container.   ABATEMENT CERTIFICATION REQUIRED
Recent events (3)
  • — J (S) $10403
  • — C (S) $10403
  • — Z (S) $10403

1926.416 A01

Serious Gravity 10 1 instance 10 exposed
Issued
Mar 17, 2025
Abate by
Mar 27, 2025
Penalty
Initial $16,550 · Current $16,550
29 CFR 1926.416(a)(1): The employer permitted employees to work in close proximity to energized, unguarded, and ungrounded electric power circuits that the employee could contact in the course of their work:   a) Generator Area- On or about September 21, 2024, employees were exposed to an electrical shock hazard from a flexible cord that was run across live two hundred forty (240) volt electrical wires that provided power to the structure.  ABATEMENT CERTIFICATION AND DOCUMENTATION REQUIRED
Recent events (3)
  • — J (S) $16550
  • — C (S) $16550
  • — Z (S) $16550

1926.501 B03

Serious Gravity 10 2 instances 6 exposed
Issued
Mar 17, 2025
Abate by
Mar 27, 2025
Penalty
Initial $16,550 · Current $16,550
29 CFR 1926.501(b)(3): Each employee in a hoist area was not protected from falling 6 feet (1.8m) or more to lower levels by guardrail systems or personal fall arrest systems:   a) Material Hoist Area- On or about September 21, 2024, employees utilizing a material hoist were exposed to a fall hazard of approximately twenty-nine (29) feet, 5 inches without the use of a fall protection system.  b) Ladder Hoist Area- On or about September 21, 2024, employees utilizing a ladder to hoist materials were exposed to a fall hazard of approximately twenty-nine (29) feet, 5 inches without the use of a fall protection system.  ABATEMENT DOCUMENTATION AND CERTIFICATION REQUIRED
Recent events (3)
  • — J (S) $16550
  • — C (S) $16550
  • — Z (S) $16550

1926.552 A01

Serious Gravity 10 2 instances 4 exposed
Issued
Mar 17, 2025
Abate by
Mar 27, 2025
Penalty
Initial $16,550 · Current $16,550
29 CFR 1926.552(a)(1): The employer did not comply with manufacturer's specifications and limitations applicable to the operation of all hoists and elevators:   a) Front Roof Material Hoist- On or about September 21, 2024, employees were exposed to a struck by hazard from a material hoist that was not assembled with all required hardware per the manufacturer instructions such as but not limited to missing bolts in splice plates.  b) Upper Roof Material Hoist- On or about September 21, 2024, employees were exposed to a struck by and caught in hazards from a material hoist that was not assembled with all required hardware per the manufactures instructions such as but not limited to guards over the belts and missing bolts in splice plates.  ABATEMENT CERTIFICATION AND DOCUMENTATION REQUIRED
Recent events (3)
  • — J (S) $16550
  • — C (S) $16550
  • — Z (S) $16550

1926.1053 B01

Serious Gravity 10 2 instances 6 exposed
Issued
Mar 17, 2025
Abate by
Mar 27, 2025
Penalty
Initial $16,550 · Current $16,550
29 CFR 1926.1053(b)(1): Portable ladders were used for access to an upper landing surface and the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder was used to gain access:  a) Front Roof Access Ladder- On or about September 21, 2024, employees working on a roof were exposed to a fall hazard of approximately eighteen (18) feet, four (4) inches from the use of a portable ladder that was used to gain access to the roof that was not extended at least three (3) feet above the upper landing surface and was not secured at its top.  b) Upper Roof Access Ladder- On or about September 21, 2024, employees working on a roof were exposed to a fall hazard of approximately twenty-eight (28) feet from the use of a portable ladder that was used to gain access to the roof that was not extended at least three (3) feet above the upper landing surface and was not secured at its top.  Abatement: With respect to all future worksites in Pennsylvania, the employer must cease and desist from permitting employees to work with pneumatic nail guns, unless each employee is wearing eye protection equipment.  Abatement certification and documentation to address the specific violation observed on or about September 21, 2024, is also required. The Date By Which Violation Must Be Abated listed below is for the specific violation observed on or about September 21, 2024. The cease and desist provision listed above is an ongoing obligation.
Recent events (3)
  • — J (S) $16550
  • — C (S) $16550
  • — Z (S) $16550

1926.1053 B05 I

Serious Gravity 5 1 instance 6 exposed
Issued
Mar 17, 2025
Abate by
Mar 27, 2025
Penalty
Initial $13,005 · Current $13,005
29 CFR 1926.1053(b)(5)(i): Non-self-supporting ladder(s) were not used at an angle such that the horizontal distance from the top support to the foot of the ladder was approximately one-quarter of the working length of the ladder:  a) Front Roof Access Ladder- On or about September 21, 2024, employees accessing the roof were exposed to a fall hazard of approximately eighteen (18) feet, four (4) inches from the use of a ladder whose base was approximately one-third of the total working length of the ladder at too shallow of an angle.  ABATEMENT CERTIFICATION REQUIRED
Recent events (3)
  • — J (S) $13005
  • — C (S) $13005
  • — Z (S) $13005

1926.1053 B09

Serious Gravity 1 1 instance 6 exposed
Issued
Mar 17, 2025
Abate by
Mar 27, 2025
Penalty
Initial $7,802 · Current $7,802
29 CFR 1926.1053(b)(9): The area around the top and bottom of ladders was not kept clear:  a) Front Roof Access Ladder- On or about September 21, 2024, employees were exposed to a fall hazard of approximately two (2) feet from a bundle of shingles placed over the bottom rung of the ladder.  ABATEMENT CERTIFICATION REQUIRED
Recent events (3)
  • — J (S) $7802
  • — C (S) $7802
  • — Z (S) $7802

1926.1053 B12

Serious Gravity 10 1 instance 6 exposed
Issued
Mar 17, 2025
Abate by
Mar 27, 2025
Penalty
Initial $16,550 · Current $16,550
29 CFR 1926.1053(b)(12): Ladders used where the employee or the ladder could contact exposed energized electrical equipment did not have nonconductive siderails:  a) Front Roof Access Ladder- On or about September 21, 2024, employees were exposed to electrical shock hazard from the use of an aluminum ladder in close contact to live electrical power lines at two hundred forty (240) volts.  ABATEMENT CERTIFICATION AND DOCUMENTATION REQUIRED
Recent events (3)
  • — J (S) $16550
  • — C (S) $16550
  • — Z (S) $16550

1926.1053 B15

Serious Gravity 10 1 instance 6 exposed
Issued
Mar 17, 2025
Abate by
Mar 27, 2025
Penalty
Initial $16,550 · Current $16,550
29 CFR 1926.1053(b)(15): Ladder(s) were not inspected by a competent person for visible defects on a periodic basis and/or after an occurrence that could have affected their safe use:   a) Front Roof Access Ladder- On or about September 21, 2024, employees working on a roof were exposed to a fall hazard of approximately eighteen (18) feet, four (4) inches from the use of a portable ladder that had not been inspected and had deficiencies such as but not limited to bent rungs and side rails.  ABATEMENT CERTIFICATION AND DOCUMENTATION REQUIRED
Recent events (3)
  • — J (S) $16550
  • — C (S) $16550
  • — Z (S) $16550

1926.1053 B16

Serious Gravity 10 1 instance 6 exposed
Issued
Mar 17, 2025
Abate by
Mar 27, 2025
Penalty
Initial $16,550 · Current $16,550
29 CFR 1926.1053(b)(16): Portable ladders with structural defects, such as, but not limited to, broken or missing rungs, cleats, or steps, broken or split rails, corroded components, or other faulty or defective components, were not either immediately marked in a manner that readily identifies them as defective, or tagged with "Do Not Use" or similar language, and were not withdrawn from service until repaired.  a) Front Roof Access Ladder- On or about September 21, 2024, employees working on a roof were exposed to a fall hazard of approximately eighteen (18) feet, four (4) inches from the use of a portable ladder with multiple structural defects.  ABATEMENT CERTIFICATION AND DOCUMENTATION REQUIRED
Recent events (3)
  • — J (S) $16550
  • — C (S) $16550
  • — Z (S) $16550

1926.102 A01

Willful Gravity 10 1 instance 6 exposed
Issued
Mar 17, 2025
Abate by
Mar 27, 2025
Penalty
Initial $165,514 · Current $165,514
29 CFR 1926.102(a)(1): The employer did not ensure that each affected employee used appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation:  a) Roof- On or about September 21, 2024, employees utilizing pneumatic nail guns were exposed to flying object hazards without the use of eye and face protection.  Abatement: With respect to all future worksites in Pennsylvania, the employer must cease and desist from permitting employees to work with pneumatic nail guns, unless each employee is wearing eye protection equipment.  Abatement certification and documentation to address the specific violation observed on or about September 21, 2024, is also required. The Date By Which Violation Must Be Abated listed below is for the specific violation observed on or about September 21, 2024. The cease and desist provision listed above is an ongoing obligation.
Recent events (3)
  • — J (W) $165514
  • — C (W) $165514
  • — Z (W) $165514

1926.501 B11

Willful Gravity 10 1 instance 6 exposed
Issued
Mar 17, 2025
Abate by
Mar 27, 2025
Penalty
Initial $165,514 · Current $165,514
29 CFR 1926.501(b)(11): Each employee on a steep roof with unprotected sides and edges 6 feet (1.8 m) or more above lower levels was not protected from falling by guardrail systems with toeboards, safety net systems, or personal fall arrest systems:  a) Southwest Roof Peak Area- On or about September 21, 2024, employees replacing a roof were exposed to a fall hazard of approximately eighteen feet (18) without the use of a fall protection system.   b) Northwest Roof Leading Edge Area - On or about September 21, 2024, employees replacing a roof were exposed to a fall hazard of approximately twenty-nine feet (29), five inches without the use of a fall protection system.  Abatement: With respect to all future worksites in Pennsylvania, the employer must cease and desist from permitting employees to work on walking/working surfaces with unprotected sides or edges 6 feet or more above a lower level, unless each employee is protected by a guardrail system, safety net system, or personal fall arrest system.  Abatement certification and documentation to address the specific violation observed on or about September 21, 2024, is also required. The Date By Which Violation Must Be Abated listed below is for the specific violation observed on or about September 21, 2024. The cease and desist provision listed above is an ongoing obligation.
Recent events (3)
  • — J (W) $165514
  • — C (W) $165514
  • — Z (W) $165514

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347770406.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.