TELFORD, PA —
OSHA Inspection: STAIRWORKS, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of STAIRWORKS, INC. in 811 TECH DR., TELFORD, PA 18969 (NAICS 321918). OSHA activity number 347770935.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- STAIRWORKS, INC.
- Site address
- 811 TECH DR.
- City
- TELFORD
- State
- PA
- ZIP
- 18969
- Mailing
- 811 TECH DR., TELFORD, PA 18969
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 321918
- Employees
- 22
- Ownership type
- A
Citations
5 citations on file for this inspection.
1910.212 A01
- Issued
- Feb 25, 2025
- Penalty
- Initial $3,215 · Current $1,750 Reduced
General-duty citation text
29 CFR 1910.212(a)(1):One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: a) 811 Tech Drive, Telford, PA 18969 - on or about September 23, 2024, a router table was lacking adequate methods of machine guarding to prevent employee(s) from making contact with the routing bit during operation.
Recent events (2)
- — I (S) $1750
- — Z (S) $3215
1910.213 M01
- Issued
- Feb 25, 2025
- Penalty
- Initial $3,215 · Current $1,750 Reduced
General-duty citation text
29 CFR 1910.213(m)(1):Cutting heads of wood shaper(s) were not enclosed with a cage or adjustable guard so designed so as to keep the operator's hand away from the cutting edge: a) 811 Tech Drive, Telford, PA 18969 - on or about September 23, 2024 and at times prior, the Grizzly Shaper G0608X did not have a machine guard installed to protect the operators.
Recent events (2)
- — I (S) $1750
- — Z (S) $3215
1910.213 P04
- Issued
- Feb 25, 2025
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.213(p)(4):Belt sanding machinery was not provided with a guard at each nip point where the sanding belt ran onto a pulley, to prevent the operator's hands or fingers from coming into contact with nip points: a) 811 Tech Drive, Telford, PA 18969 - on or about September 23, 2024 and at times prior, a Jet Belt/Disc Sander was lacking adequate methods of machine guarding at the point of operation to protect the operators from coming in contact with nip points. b) a) 811 Tech Drive, Telford, PA 18969 - on or about September 23, 2024 and at times prior, a Powermatic Oscillating Edge Sander was lacking adequate methods of machine guarding at the point of operation to protect employees from ingoing nip points and rotating parts.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.213 H01
- Issued
- Feb 25, 2025
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.213(h)(1):The sides of the lower exposed portion of the blade of radial saw(s) were not guarded to the full diameter of the blade by a device that automatically adjusted itself to the thickness of the stock and remained in contact with the maximum protection possible for the operation being performed. a) 811 Tech Drive, Telford, PA 18969 - on or about September 23, 2024 and at times prior, Delta Radial Arm Saws did not have a machine guard to protect the operators from coming in contact with the lower exposed portion of the blade.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.303 G01
- Issued
- Feb 25, 2025
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(g)(1):Sufficient access and working space was not provided and maintained about all electric equipment (operating at 600 volts, nominal, or less to ground) to permit ready and safe operation and maintenance of such equipment: a) 811 Tech Drive, Telford, PA 18969: Back of wood shop - On or about September 23, 2024 and at times prior, sufficient access to the electrical panels was not readily available to permit safe operation and maintenance of the equipment.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Stairworks, INC.
View Stairworks, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 321918)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347770935.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.