BROWNSVILLE, TX —
OSHA Inspection: MVP PLASTICS SA, LLC
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of MVP PLASTICS SA, LLC in 1930 ANEI CIRCLE, BROWNSVILLE, TX 78521 (NAICS 326199). OSHA activity number 347774101.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- MVP PLASTICS SA, LLC
- Site address
- 1930 ANEI CIRCLE
- City
- BROWNSVILLE
- State
- TX
- ZIP
- 78521
- Mailing
- 1930 ANEI CIRCLE, BROWNSVILLE, TX 78521
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 326199
- Employees
- 62
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.147 C04 II B
- Issued
- Jan 17, 2025
- Abate by
- Feb 6, 2025
- Penalty
- Initial $11,585 · Current $6,951 Reduced
General-duty citation text
1910.147(c)(4)(ii)(B) The energy control procedures did not clearly and specifically outline the steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy. On or about September 23, 2024, and at times prior thereto, the energy control procedures for plastic mold injection plant machines and equipment were not developed and used by employees for the control of hazardous energies, while performing servicing, cleaning and unjamming operations.
Recent events (2)
- — I (S) $6951
- — Z (S) $11585
1910.334 A03 I
- Issued
- Jan 17, 2025
- Penalty
- Initial $11,585 · Current $6,951 Reduced
General-duty citation text
29 CFR 1910.334(a)(3)(i): A flexible cord used with grounding type equipment shall contain an equipment grounding conductor: On or about September 23, 2024, and at times prior thereto, in the Mold Injection Plastic Presses production department, employees used equipment that had a damaged electric flexible cord with missing grounding conductor that affected the safe operation of the machine system while conducting plastic parts production.
Recent events (2)
- — I (S) $6951
- — Z (S) $11585
More inspections in this industry (NAICS 326199)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347774101.