NILES, IL —
OSHA Inspection: BAWADI CONSTRUCTION INC.
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of BAWADI CONSTRUCTION INC. in 7007 W DEMPSTER ST., NILES, IL 60714 (NAICS 236220). OSHA activity number 347776981.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- BAWADI CONSTRUCTION INC.
- Site address
- 7007 W DEMPSTER ST.
- City
- NILES
- State
- IL
- ZIP
- 60714
- Mailing
- 18250 HARWOOD AVE, HOMEWOOD, IL 60422
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236220
- Employees
- 2
- Ownership type
- A
Citations
6 citations on file for this inspection.
1910.134 C01
- Issued
- Dec 18, 2024
- Abate by
- Feb 28, 2025
- Penalty
- Initial $3,111 · Current $1,800 Reduced
9000
General-duty citation text
29 CFR 1910.134(c)(1): A written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not established and implemented for required respirator use: (Construction Reference 1926.103) a) On or about September 24, 2024, the employer did not ensure that a that a written respiratory protection program was established for employees required to wear respiratory protection, including 3M 6200 elastomeric half facepiece respirator and 3M 8511 N95 filtering facepiece respirator, when cutting and/or chipping concrete with hand powered tools. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
- — I (S) $1800
- — Z (S) $3111
1910.134 E01
- Issued
- Dec 18, 2024
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace: (Construction Reference 1926.103) a) On or about September 24, 2024, the employer did not ensure that employees were medically evaluated prior to wearing respiratory protection, including 3M 6200 elastomeric half facepiece respirator and 3M 8511 N95 filtering facepiece respirator, when cutting and/or chipping concrete with hand powered tools. No abatement certification or documentation is required for this item.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.134 F02
- Issued
- Dec 18, 2024
- Abate by
- Feb 28, 2025
- Penalty
- Initial $0 · Current $0
9000
General-duty citation text
29 CFR 1910.134(f)(2): Employee(s) using tight-fitting facepiece respirators were not fit tested prior to initial use of the respirator: (Construction Reference 1926.103) a) On or about September 24, 2024, the employer did not ensure that employees were fit tested prior to wearing a respiratory protection, including 3M 6200 elastomeric half facepiece respirator and 3M 8511 N95 filtering facepiece respirator, when cutting and/or chipping concrete. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.134 K01
- Issued
- Dec 18, 2024
- Abate by
- Feb 28, 2025
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(k)(1): The employer did not provide respirator training that would ensure each employee could demonstrate knowledge of items in section (i)-(vii): (Construction Reference 1926.103) a) On or about September 23, 2024, the employer did not ensure that employees demonstrated knowledge on why the respirator was necessary and how improper fit, usage, storage or maintenance can compromise the protective effect of the respirator. The employees were required to wear 3M 6200 elastomeric half facepiece respirator and 3M 8511 N95 filtering facepiece respirator, when working indoor cutting and/or chipping concrete. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.1153 I02 I A
- Issued
- Dec 18, 2024
- Abate by
- Feb 28, 2025
- Penalty
- Initial $3,111 · Current $1,700 Reduced
9000
General-duty citation text
29 CFR 1926.1153(i)(2)(i)(A): The employer did not ensure that each employee covered by this section could demonstrate knowledge and understanding of the health hazards associated with exposure to respirable crystalline silica: a) On or about September 24, 2024, the employer did not ensure that employees chipping a cinder block wall and a hole on the concrete floor, containing up to 8% of silica quartz, were trained on the health hazards associate to respirable crystalline silica. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
- — I (S) $1700
- — Z (S) $3111
1926.1153 G01
- Issued
- Dec 18, 2024
- Abate by
- Feb 28, 2025
- Penalty
- Initial $0 · Current $0
9000
General-duty citation text
29 CFR 1926.1153(g)(1): The employer did not establish and implement a written exposure control plan: a) On or about September 24, 2024, the employer did not establish and implement a site specific written exposure control plan that outlined at least the following elements: descriptions of the tasks that can expose employees to silica, descriptions of the work practices, respiratory protection, engineering controls, description of housekeeping measures, and if necessary, procedures to limit access to areas to reduce employee exposure to crystalline silica. Employees were working indoor cutting and/or chipping concrete containing up to 8% crystalline silica quartz. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Bawadi Construction INC.
View Bawadi Construction INC.'s full OSHA safety record →
More inspections in this industry (NAICS 236220)
More inspections in IL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347776981.