LEANDER, TX —
OSHA Inspection: AJR CONSTRUCTION AND LATH, LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of AJR CONSTRUCTION AND LATH, LLC in 1268 MANUELA LANE, LEANDER, TX 78641 (NAICS 238310). OSHA activity number 347801649.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- AJR CONSTRUCTION AND LATH, LLC
- Site address
- 1268 MANUELA LANE
- City
- LEANDER
- State
- TX
- ZIP
- 78641
- Mailing
- 1 GABRIELS BLUFF DRIVE, GEORGETOWN, TX 78626
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238310
- Employees
- 4
- Ownership type
- A
Citations
6 citations on file for this inspection.
1926.451 E01
- Issued
- Oct 18, 2024
- Penalty
- Initial $2,765 · Current $1,659 Reduced
General-duty citation text
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface were not used. Cross braces were used as a means of access. Devine Lake New Home Community: On or about October 7, 2024, and at times prior thereto, employees installed lath and waterproof felt from supported scaffolds without being provided ladders as a means of access and egress.
Recent events (2)
- — I (S) $1659
- — Z (S) $2765
1926.451 B02
- Issued
- Oct 18, 2024
- Penalty
- Initial $2,074 · Current $1,244 Reduced
General-duty citation text
29 CFR 1926.451(b)(2): Scaffold platforms and walkways were not at least 18 inches wide: Devine Lake New Home Community: On or about October 7, 2024, and at times prior thereto, an employee installed lath from supported scaffolds without the scaffold planks being at least 18 inches wide.
Recent events (2)
- — I (S) $1244.4
- — Z (S) $2074
1926.451 G01
- Issued
- Oct 18, 2024
- Penalty
- Initial $2,351 · Current $1,411 Reduced
General-duty citation text
29 CFR 1926.451(g)(1): Each employee on a scaffold more than 10 feet (3.1m) above a lower level was not protected from falling to that lower level by fall protection established in accordance with paragraphs (g)(1)(i) through (vii) of this section: Devine Lake New Home Community: On or about October 7, 2024, and at times prior thereto, employees installed lath to the exterior of a new home under construction while working from scaffold systems above 10-feet high without a fall protection system.
Recent events (2)
- — I (S) $1410.6
- — Z (S) $2351
1926.454 A
- Issued
- Oct 18, 2024
- Abate by
- Nov 14, 2024
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.454(a): The employer did not have each employee who performed work while on a scaffold trained by a person qualified in the subject matter to recognize the hazards associated with the type of scaffold being used and to understand the procedures to control or minimize those hazards. Devine Lake New Home Community: On or about October 7, 2024, and at times prior thereto, employees used a supported scaffold to install lath to a new home under construction without being provided scaffold training.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.451 H02 II
- Issued
- Oct 18, 2024
- Penalty
- Initial $1,763 · Current $1,058 Reduced
General-duty citation text
29 CFR 1926.451(h)(2)(ii): A toeboard was not erected along the edge of platforms more than 10 feet (3.1 m) above lower levels for a distance sufficient to protect employees below: Devine Lake New Home Community: On or about October 7, 2024, and at times prior thereto, an employee used a supported scaffold more than 10 feet above the ground without toeboards while work was being done above other workers.
Recent events (2)
- — I (S) $1057.8
- — Z (S) $1763
1926.501 B13
- Issued
- Oct 18, 2024
- Penalty
- Initial $3,526 · Current $2,116 Reduced
General-duty citation text
29 CFR 1926.501(b)(13): Employee(s) engaged in residential construction 6 feet (1.8 m) or more above lower levels were not protected from falling by the use of guardrail systems, safety net systems or personal fall arrest systems nor was an alternative fall protection plan which meets the requirements of 1926.502(k) developed and implemented: Devine Lake New Home Community: On or about October 7, 2024, and at times prior thereto, an employee installed lath to the exterior of a new home under construction while working from the 1st story roof without a fall protection system.
Recent events (2)
- — I (S) $2115.6
- — Z (S) $3526
More inspections at AJR Construction and Lath, LLC
View AJR Construction and Lath, LLC's full OSHA safety record →
More inspections in this industry (NAICS 238310)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347801649.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.