Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: BOULDER CONSTRUCTION, L.L.C.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of BOULDER CONSTRUCTION, L.L.C. in 4020 BROADWAY, QUINCY, IL 62301 (NAICS 238160). OSHA activity number 347803983.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Boulder Construction, L.L.C. — free Get an email when a new federal OSHA severe-injury report for Boulder Construction, L.L.C. is published. One employer, no account, unsubscribe in one click.
Site address
4020 BROADWAY
City
QUINCY
State
IL
ZIP
62301
Mailing
2075 CORPORATE CIRCLE, CAPE GIRARDEAU, MO 63703
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
5
Ownership type
A

6 citations on file for this inspection.

1926.20 B02

Serious Gravity 5 1 instance 4 exposed
Issued
Nov 18, 2024
Abate by
Dec 4, 2024
Penalty
Initial $8,067 · Current $4,840 Reduced
29 CFR 1926.20(b)(2):  The employer did not initiate and maintain programs which provided for frequent and regular inspections of the job site, materials, and equipment to be made by a competent person:  On or about October 8, 2024, employees were exposed to fall hazards while performing construction activities and the employer had not ensured a competent person conducted frequent and regular inspections of the worksite and equipment to identify the workplace hazards.
Recent events (2)
  • — I (S) $4840.2
  • — Z (S) $8067

1926.451 G04 I

Serious Gravity 5 1 instance 3 exposed
Issued
Nov 18, 2024
Abate by
Dec 4, 2024
Penalty
Initial $0 · Current $0
29 CFR 1926.451(g)(4)(i):  Guardrail systems were not installed along all open sides and ends of platforms:  On or about October 8, 2024, employees were exposed to a fall hazard of up to approximately 21 feet while using a scissor lift because guardrails were not used on all open sides of the platform.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.501 B01

Serious Gravity 10 1 instance 2 exposed
Issued
Nov 18, 2024
Abate by
Dec 4, 2024
Penalty
Initial $11,292 · Current $6,775 Reduced
29 CFR 1926.501(b)(1):  Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems:  On or about October 8, 2024, employees were exposed to a fall hazard of approximately 12 feet while working from the top plate of a storage building because suitable fall protection was not used.
Recent events (2)
  • — I (S) $6775.4
  • — Z (S) $11292

1926.501 B10

Serious Gravity 10 1 instance 3 exposed
Issued
Nov 18, 2024
Abate by
Dec 4, 2024
Penalty
Initial $0 · Current $0
29 CFR 1926.501(b)(10):  Each employee engaged in roofing activities on low-slope roofs, with unprotected sides and edges 6 feet (1.8 m) or more above lower levels, was not protected from falling by guardrail systems, safety net systems, personal fall protection:  On or about October 8, 2024, employees were exposed to a fall hazard of approximately 21 feet while installing roof coping cap because a suitable fall protection system was not used.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.1053 B01

Serious Gravity 5 1 instance 2 exposed
Issued
Nov 18, 2024
Abate by
Dec 4, 2024
Penalty
Initial $8,067 · Current $4,840 Reduced
29 CFR 1926.1053(b)(1):  Portable ladders were used for access to an upper landing surface and the ladder side rails did not extend at least 3 feet (0.9 m) above the upper landing surface to which the ladder was used to gain access:  On or about October 8, 2024, employees were exposed to a fall hazard of approximately 12 feet while ascending and descending a ladder onto the top plate of a storage building because the side rails did not extend at least three feet above the landing surface.
Recent events (2)
  • — I (S) $4840.4
  • — Z (S) $8067

1926.1053 B04

Serious Gravity 5 1 instance 2 exposed
Issued
Nov 18, 2024
Abate by
Dec 4, 2024
Penalty
Initial $0 · Current $0
29 CFR 1926.1053(b)(4):  Ladder(s) were used for purposes other than the purpose for which they were designed:  On or about October 8, 2024, employees were exposed to a fall hazard of approximately 12 feet when using a step ladder leaned up against a wall because the self-supporting legs were not in the open position.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View Boulder Construction, L.L.C.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347803983.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.