BELLWOOD, PA —
OSHA Inspection: SPECIALTY BUILDING PRODUCTS
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of SPECIALTY BUILDING PRODUCTS in 1620 N TUCKAHOE STREET, BELLWOOD, PA 16617 (NAICS 423310). OSHA activity number 347804148.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- SPECIALTY BUILDING PRODUCTS
- Site address
- 1620 N TUCKAHOE STREET
- City
- BELLWOOD
- State
- PA
- ZIP
- 16617
- Mailing
- 2160 SATELLITE BOULEVARD SUITE 450, DULUTH, GA 30097
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 423310
- Employees
- 60
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.28 B15
- Issued
- Jan 13, 2025
- Penalty
- Initial $14,518 · Current $14,518
General-duty citation text
29 CFR 1910.28(b)(15): 29 CFR 1910.28(b)(15): Walking-working surfaces not otherwise addressed. Except as provided elsewhere in this section or by other subparts of this part, the employer did not ensure each employee on a walking/working surface 4 feet (1.2 m) or more above a lower level is protected from falling by one of the systems listed in 1910.28(b)(15)(i)-(iii). a.) Front Entrance Way, 1620 N Tuckahoe Street, Bellwood, PA 16617: on or about October 4, 2024, An employee was working from a work platform that was not firmly secured to the lifting carriage and/or forks of a Hyster 90 - 1049 Fortis Forklift brand powered industrial truck (model number: H90FT, serial number U005V04747R) through the use of fall protection per the requirements of the standard, guardrails 48 inches in height.
Recent events (2)
- — I (S) $14518
- — Z (S) $14518
1910.178 A04
- Issued
- Jan 13, 2025
- Penalty
- Initial $8,296 · Current $482 Reduced
General-duty citation text
29 CFR 1910.178(a)(4): Modifications or additions which affect capacity and safe operation of powered industrial truck were performed by the employer without the manufacturer's prior written approval: a.) Front Entrance Way, 1620 N Tuckahoe Street, Bellwood, PA 16617: Observed on or about October 4, 2024, a work platform used with a hyster 90-1049 Fortis forklift to lift personnel was not approved by the manufacturer. Employees using the Sidasu Safety Cage work platform to perform building maintenance or to secure signs from the upper level of the front entrance way of the building were exposed to a fall hazard of approximately 12 feet to the concrete ground below.
Recent events (2)
- — I (O) $482
- — Z (S) $8296
1910.157 E01
- Issued
- Jan 13, 2025
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.157(e)(1):The employer shall be responsible for the inspection, maintenance and testing of all portable fire extinguishers in the workplace. a.) 1620 N Tuckahoe Street, Bellwood, PA 16617: Observed on or about October 4, 2024, portable fire extinguisher mounted onto the power industrial fork truck did not have the proper labeling indicating the current inspection year.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections in this industry (NAICS 423310)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347804148.