Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: S&L COLD STORAGE INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of S&L COLD STORAGE INC. in 450 SWEDESBORO AVENUE, MICKLETON, NJ 08056 (NAICS 493120). OSHA activity number 347804544.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch S&L Cold Storage INC. — free Get an email when a new federal OSHA severe-injury report for S&L Cold Storage INC. is published. One employer, no account, unsubscribe in one click.
Site address
450 SWEDESBORO AVENUE
City
MICKLETON
State
NJ
ZIP
08056
Mailing
450 SWEDESBORO AVENUE, MICKLETON, NJ 08056
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
493120
Employees
35
Ownership type
A

7 citations on file for this inspection.

1910.133 A01

Serious Gravity 1 1 instance 20 exposed
Issued
Jan 2, 2025
Abate by
Jan 29, 2025
Penalty
Initial $4,839 · Current $3,150 Reduced
29 CFR 1910.133(a)(1): The employer did not ensure that each affected employee used appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors or potentially injurious light radiation.  a) S&L Cold Storage Inc. -  Packing area:  The employer did not ensure employees were wearing safety glasses while using the compressed air set between 60 to  80 P.S.I. while cleaning equipment , such as, but not limited to,  PTI Packline, multiple GIRO Girbaggers smart systems, Model UBS65, and Static Weighters, Daumar Type CEA-55, occurred on or about 10/08/2024.
Recent events (2)
  • — I (S) $3150
  • — Z (S) $4839

1910.242 B

Serious Gravity 1 1 instance 20 exposed
Issued
Jan 2, 2025
Abate by
Mar 20, 2025
Penalty
Initial $0 · Current $0
29 CFR 1910.242(b):  Compressed air was used for cleaning purposes was not reduced to less than 30 p.s.i.   a) S&L Cold Storage Inc. -  Packing area:  Compressed air to clean equipment, such as, but not limited to,  PTI Packline, multiple GIRO Girbaggers smart systems, Model UBS65, and Static Weighters, Daumar Type CEA-55, by employees was between 60 to 80 p.s.i., occurred on or about 10/08/2024.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.147 C01

Serious Gravity 10 2 instances 30 exposed
Issued
Jan 2, 2025
Abate by
Feb 28, 2025
Penalty
Initial $11,292 · Current $7,350 Reduced
29 CFR  1910.147(c)(1):  The employer did not establish a program consisting of energy control procedures, employee training and periodic inspections to ensure that before any employee performs any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment was isolated from the energy source and rendered inoperative.  a) S&L Cold Storage Inc. -  Maintenance department:  The employer did not establish a Lock Out/Tag Out Program consisting of energy control procedures, employee training, and periodic inspections to protect employees against the unexpected energization of equipment when servicing, making adjustments, replacing parts, cleaning or unjamming machines.  Machinery  includes, but is not limited to, PTI Packline, GIRO Girbagger smart system Model UBS65, Static Weighter, Daumar Type CEA-55, occurred on or about 10/08/2024.  a) S&L Cold Storage Inc. -  Sanitation department: The employer did not establish a Lock Out/Tag Out Program consisting of energy control procedures, employee training, and periodic inspections to protect employees against the unexpected energization of equipment when performing cleaning and sanitation in machinery including but is not limited to, PTI Packline, GIRO Girbagger smart system Model UBS65, Static Weighter, Daumar Type CEA-55, occurred on or about 10/08/2024.
Recent events (2)
  • — I (S) $7350
  • — Z (S) $11292

1910.176 B

Serious Gravity 10 1 instance 50 exposed
Issued
Jan 2, 2025
Abate by
Jan 29, 2025
Penalty
Initial $11,292 · Current $7,350 Reduced
29 CFR  1910.176(b): Material stored in tiers was not stacked, blocked, interlocked or limited in height so that it was stable and secure against sliding and collapse:  a) S&L Cold Storage Inc. -  Packing area: The employer failed to ensure that employees were properly securing, interlocking, and limiting the height of loads to prevent sliding, tilting, or collapsing. Occurred on or about 10/08/2024.
Recent events (2)
  • — I (S) $7350
  • — Z (S) $11292

1910.178 O01

Serious Gravity 10 1 instance 50 exposed
Issued
Jan 2, 2025
Abate by
Jan 29, 2025
Penalty
Initial $0 · Current $0
29 CFR  1910.178(o)(1): The employer did not ensure that only stable or safely arranged loads were handled:   a) S&L Cold Storage Inc. -  Packing area: The employer failed to ensure that employees were properly securing, interlocking, and limiting the height of loads on forklifts to prevent sliding, tilting, or collapsing. On 9/11/24 an 8 foot high stack of product fell onto an employee as the forklift operator was turning the lift, the employee was taken to the emergency room.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.178 G02

Serious Gravity 1 1 instance 5 exposed
Issued
Jan 2, 2025
Abate by
Jan 29, 2025
Penalty
Initial $4,839 · Current $3,150 Reduced
29 CFR 1910.178(g)(2):  The battery charging apparatus for industrial trucks located in battery changing and charging installations was not protected from damage by trucks:  a) S&L Cold Storage Inc. -  Forklift charging area: The facility did not protect the battery charging apparatuses from damage.  The charging cables on the ECOTEC Model# ACCESS 13/36, S/N 23C7457 battery had damaged cords with damaged outer casing, observed on or about 10/08/2024.
Recent events (2)
  • — I (S) $3150
  • — Z (S) $4839

1910.176 A

Other-than-serious 1 instance 50 exposed
Issued
Jan 2, 2025
Abate by
Jan 29, 2025
Penalty
Initial $0 · Current $0
29 CFR  1910.176(a): Use of mechanical equipment. Where mechanical handling equipment is used, sufficient safe clearances shall be allowed for aisles, at loading docks, through doorways and wherever turns or passage must be made. Aisles and passageways shall be kept clear and in good repair, with no obstruction across or in aisles that could create a hazard. Permanent aisles and passageways shall be appropriately marked.   a) S&L Cold Storage Inc. -  Throughout the manufacturing area:  Pallets of finished product were stacked around the work areas blocking the view of the forklift operators to employees working between the stacks of product and the packing lines.  Occurred on or about 10/08/2024.  b) S&L Cold Storage Inc.-Throughout the manufacturing area: Employees are exposed to struck by hazards due to empty boxes and trash stacked around the works areas blocking the view of the forklift operators to employees working between the stacks of boxes and trash and the packing lines.   Occurred on or about 10/08/2024.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347804544.