EXETER, RI —
OSHA Inspection: HELPING HOMES LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of HELPING HOMES LLC in 231 NOOSENECK ROAD, EXETER, RI 02822 (NAICS 238160). OSHA activity number 347807919.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- HELPING HOMES LLC
- Site address
- 231 NOOSENECK ROAD
- City
- EXETER
- State
- RI
- ZIP
- 02822
- Mailing
- 4 2ND STREET, COVENTRY, RI 02816
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 2
- Ownership type
- A
Citations
5 citations on file for this inspection.
1926.100 A
- Issued
- Jan 22, 2025
- Penalty
- Initial $4,965 · Current $0 Reduced
General-duty citation text
29 CFR 1926.100(a): Employees working in areas where there was a possible danger of head injury from impact, or falling or flying objects, or from electrical shock and burns, were not protected by protective helmets. a) Worksite: On or about 10-10-2024, an employee was exposed to struck-by hazards while working on a roof level below roofers on a higher roof level.
Recent events (3)
- — F (S) $0
- — C (S) $4965
- — Z (S) $4965
1926.102 A01
- Issued
- Jan 22, 2025
- Penalty
- Initial $3,547 · Current $0 Reduced
General-duty citation text
29 CFR 1926.102(a)(1): The employer shall ensure that each affected employee uses appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation. (a) Worksite: On or about 10-10-2024, employees were exposed to struck-by hazards from utilizing pneumatic nail guns during residential roofing without any means of eye or face protection.
Recent events (3)
- — F (S) $0
- — C (S) $3547
- — Z (S) $3547
1926.501 B13
- Issued
- Jan 22, 2025
- Penalty
- Initial $4,965 · Current $0 Reduced
General-duty citation text
29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employees provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b). Worksite: On or about 10-10-2024, employees were exposed to fall hazards while removing and installing roofing material at a height of approximately 13 feet above the lower level without any means of fall protection.
Recent events (3)
- — F (S) $0
- — C (S) $4965
- — Z (S) $4965
1926.1053 B10
- Issued
- Jan 22, 2025
- Penalty
- Initial $3,547 · Current $0 Reduced
General-duty citation text
29 CFR 1926.1053(b)(10): The tops of a non-self-supporting ladder were not placed with the two rails supported equally. (a) Worksite: On or about 10-10-2024, employees were exposed to fall hazards by ascending and descending an extension ladder that was set-up with its siderails leaning against the downward slope of the roof surface they were working from.
Recent events (3)
- — F (S) $0
- — C (S) $3547
- — Z (S) $3547
1926.1053 B12
- Issued
- Jan 22, 2025
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1053(b)(12): Ladders shall have nonconductive siderails if they are used where the employee or the ladder could contact exposed energized electrical equipment, except as provided in 1926.955(c) of this part. (a) Worksite: On or about 10-10-2024, employees were exposed to electrical type hazards from ascending and descending an aluminum extension ladder that was set-up approximately 2-feet from the live electrical power feed coming into the structure.
Recent events (3)