Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,645Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: MANUEL TAMAY DBA MANUEL TAMAY

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of MANUEL TAMAY DBA MANUEL TAMAY in 2202 EWING AVENUE, EVANSTON, IL 60201 (NAICS 238160). OSHA activity number 347808974.

Watch Manuel Tamay DBA Manuel Tamay — free Get an email when a new federal OSHA severe-injury report for Manuel Tamay DBA Manuel Tamay is published. One employer, no account, unsubscribe in one click.
Site address
2202 EWING AVENUE
City
EVANSTON
State
IL
ZIP
60201
Mailing
2837 N MENARD AVENUE, CHICAGO, IL 60634
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Last modified
Data loaded
NAICS code
238160
Employees
4
Ownership type
A

3 citations on file for this inspection.

1903.19 C01

Other-than-serious 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $398.00 · Current $398.00
29 CFR  1903.19(c)(1):29 CFR 1903.19(c)(1): The employer did not certify to OSHA, within 10 calendar days after the abatement date, that the cited violation had been abated:   a) Manuel Tamay dba Manuel Tamay., failed to certify to OSHA within 10 calendar days after the abatement date that each of the following cited violations had been corrected:  Citation Number Item Number Abatement Date 01 01 02-13-2025 01 02 02-13-2025  In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF THE CORRECTIVE ACTION WORKSHEET).
Recent events (1)
  • — Z (O) $398

1926.501 B13

Serious Gravity 10 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $4965.00 · Current $4965.00
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b):  a) On October 9, 2024, employees installing skylights from the roof of a residential structure were not protected from fall hazards while working at an elevation of approximately 13 feet above the ground.  In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (1)
  • — Z (S) $4965

1926.1053 B01

Serious Gravity 5 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $3547.00 · Current $3547.00
29 CFR 1926.1053(b)(1): Portable ladders were used for access to an upper landing surface and the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder was used to gain access:  a) On October 9, 2024, an extension ladder used by employees to access and egress the roof did not have its side rails extended at least 3 feet above the roof eave.   In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (1)
  • — Z (S) $3547

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347808974.