OSHA Inspection: GEOQUIP, INC.

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of GEOQUIP, INC. in 7351 OVERLAND RD, ORLANDO, FL 32810 (NAICS 332710). OSHA activity number 347815276.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Geoquip, INC. — free Get an email when a new federal OSHA severe-injury report for Geoquip, INC. is published. One employer, no account, unsubscribe in one click.
Establishment
GEOQUIP, INC.
Site address
7351 OVERLAND RD
City
ORLANDO
State
FL
ZIP
32810
Mailing
7351 OVERLAND RD, ORLANDO, FL 32810
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332710
Employees
7
Ownership type
A

3 citations on file for this inspection.

1910.157 C01

Serious Gravity 5 1 instance 4 exposed
Issued
Jan 14, 2025
Penalty
Initial $0 · Current $0
29 CFR  1910.157(c)(1):Portable fire extinguishers were not mounted, located and identified so that they were readily accessible without subjecting the employees to injuries:  a) On or about October 15, 2024,  at the machine shop (northside), employees were exposed to burns and asphyxiation hazards in that the fire extinguisher was blocked and/or obstructed by a blue drum, and  wood pieces.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.303 G01

Serious Gravity 5 1 instance 4 exposed
Issued
Jan 14, 2025
Penalty
Initial $0 · Current $0
29 CFR  1910.303(g)(1): Sufficient access and working space was not provided and maintained about all electric equipment (operating at 600 volts, nominal, or less to ground) to permit ready and safe operation and maintenance of such equipment:    a) On or about October 15 , 2024, in the machine shop (east side) the access to two electrical panel boxes was obstructed by  galvanized fencing pieces  exposing employees to electrical hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.1200 E01

Serious Gravity 5 1 instance 4 exposed
Issued
Jan 14, 2025
Penalty
Initial $2,765 · Current $1,659 Reduced
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and maintain at the workplace a written hazard communication program which describes how the criteria specified in paragraphs (f), (g), & (h) of this section for labels and other forms of warning, safety data sheets, and employee information and training will be met, and which also includes items (i) and (ii) of this subparagraph:  a.) On or about October 15, 2024, in the machine shop employee utilizing paint chemical Ultra Promax Cola Red, Product Code 80-858  OSHA PEL 10.9 Vol %,  the employer had not developed or implemented the requirements of a hazard communication program.