ORLANDO, FL —
OSHA Inspection: GEOQUIP, INC.
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of GEOQUIP, INC. in 7351 OVERLAND RD, ORLANDO, FL 32810 (NAICS 332710). OSHA activity number 347815276.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- GEOQUIP, INC.
- Site address
- 7351 OVERLAND RD
- City
- ORLANDO
- State
- FL
- ZIP
- 32810
- Mailing
- 7351 OVERLAND RD, ORLANDO, FL 32810
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332710
- Employees
- 7
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.157 C01
- Issued
- Jan 14, 2025
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.157(c)(1):Portable fire extinguishers were not mounted, located and identified so that they were readily accessible without subjecting the employees to injuries: a) On or about October 15, 2024, at the machine shop (northside), employees were exposed to burns and asphyxiation hazards in that the fire extinguisher was blocked and/or obstructed by a blue drum, and wood pieces.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.303 G01
- Issued
- Jan 14, 2025
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(g)(1): Sufficient access and working space was not provided and maintained about all electric equipment (operating at 600 volts, nominal, or less to ground) to permit ready and safe operation and maintenance of such equipment: a) On or about October 15 , 2024, in the machine shop (east side) the access to two electrical panel boxes was obstructed by galvanized fencing pieces exposing employees to electrical hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.1200 E01
- Issued
- Jan 14, 2025
- Penalty
- Initial $2,765 · Current $1,659 Reduced
General-duty citation text
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and maintain at the workplace a written hazard communication program which describes how the criteria specified in paragraphs (f), (g), & (h) of this section for labels and other forms of warning, safety data sheets, and employee information and training will be met, and which also includes items (i) and (ii) of this subparagraph: a.) On or about October 15, 2024, in the machine shop employee utilizing paint chemical Ultra Promax Cola Red, Product Code 80-858 OSHA PEL 10.9 Vol %, the employer had not developed or implemented the requirements of a hazard communication program.
Recent events (2)
- — I (S) $1659
- — Z (S) $2765
More inspections in this industry (NAICS 332710)
More inspections in FL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347815276.