NORTH LITTLE ROCK, AR —
OSHA Inspection: FUSIONSITE LITTLE ROCK LLC
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of FUSIONSITE LITTLE ROCK LLC in 924 WEST 15TH STREET SUITE A, NORTH LITTLE ROCK, AR 72114 (NAICS 562991). OSHA activity number 347817686.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- FUSIONSITE LITTLE ROCK LLC
- Site address
- 924 WEST 15TH STREET SUITE A
- City
- NORTH LITTLE ROCK
- State
- AR
- ZIP
- 72114
- Mailing
- PO BOX 34033, LITTLE ROCK, AR 72203
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 562991
- Employees
- 25
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.110 F02 I
- Issued
- Mar 21, 2025
- Abate by
- Apr 16, 2025
- Penalty
- Initial $9,457 · Current $6,620 Reduced
General-duty citation text
29 CFR 1910.110(f)(2)(i): LP-Gas Containers were not stored in a manner to minimize exposure to excessive temperature rise, physical damange, or tampering by unauthorized persons: On or about October 16, 2024, in the storeroom, propane fuel tanks used as a fuel source for forklifts, were not properly stored and secured from damage.
Recent events (2)
- — I (S) $6620
- — Z (S) $9457
1910.147 C01
- Issued
- Mar 21, 2025
- Abate by
- Apr 16, 2025
- Penalty
- Initial $16,550 · Current $11,585 Reduced
General-duty citation text
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative: On or about October 2, 2024, employees were performing servicing activities such as but not limited to changing the hook length on Swaploader trucks without the employer having an established energy control program.
Recent events (2)
- — I (S) $11585
- — Z (S) $16550
1904.39 A02
- Issued
- Mar 21, 2025
- Penalty
- Initial $11,823 · Current $8,276 Reduced
General-duty citation text
29 CFR 1904.39(a)(2): The employer did not report within 24-hours a work-related incident resulting in in-patient hospitalization, amputation or the loss of an eye: On or about October 5, 2024, an employee sustained a work-related injury resulting in an amputation; the employer did not report the incident to OSHA within 24-hours.
Recent events (2)
- — I (O) $8276
- — Z (O) $11823
More inspections in this industry (NAICS 562991)
More inspections in AR
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347817686.