Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: COLUMBINE CORPORATION

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of COLUMBINE CORPORATION in INDEPENDENCE CONTRACT DRILLING (ICD) RIG #332 VIPER 53-47 A 5.81 MILES NE DIRECTION FROM MENTONE, MENTONE, TX 79754 (NAICS 213112). OSHA activity number 347818882.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Columbine Corporation — free Get an email when a new federal OSHA severe-injury report for Columbine Corporation is published. One employer, no account, unsubscribe in one click.
Site address
INDEPENDENCE CONTRACT DRILLING (ICD) RIG #332 VIPER 53-47 A 5.81 MILES NE DIRECTION FROM MENTONE
City
MENTONE
State
TX
ZIP
79754
Mailing
17 EAST INDUSTRIAL LOOP, MIDLAND, TX 79701
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
213112
Employees
3
Ownership type
A

2 citations on file for this inspection.

1910.305 G01 IV C

Other-than-serious 1 instance 3 exposed
Issued
Oct 31, 2024
Abate by
Nov 13, 2024
Penalty
Initial $906 · Current $906
29 CFR  1910.305(g)(1)(iv)(C): Unless specifically permitted otherwise in paragraph (g)(1)(ii) of this section, flexible cords and cables may not be used: where run through doorways, windows, or similar openings.  On or about October 16, 2024, at the Mud Logger's work trailer, employees utilized an electrical extension cord which was run through the side window to operate the Mud Logger's test pump(s).
Recent events (1)
  • — Z (O) $906

1910.305 J02 IV

Other-than-serious 1 instance 3 exposed
Issued
Oct 31, 2024
Abate by
Nov 13, 2024
Penalty
Initial $906 · Current $906
29 CFR 1910.305(j)(2)(iv): A receptacle installed in a wet or damp location was not suitable for the location:   On or about October 16, 2024, on the inside of the Mud Logger's work trailer, employees utilized a sink (water source) in close proximity to an electrical outlet receptable which was not protected by GFCI.
Recent events (1)
  • — Z (O) $906

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347818882.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.