Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: HOLDEN MACHINE & FABRICATION

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of HOLDEN MACHINE & FABRICATION in 2 BUSINESS AVENUE, HOLDEN, WV 25625 (NAICS 332710). OSHA activity number 347820375.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Holden Machine & Fabrication — free Get an email when a new federal OSHA severe-injury report for Holden Machine & Fabrication is published. One employer, no account, unsubscribe in one click.
Site address
2 BUSINESS AVENUE
City
HOLDEN
State
WV
ZIP
25625
Mailing
P.O. BOX 678, HOLDEN, WV 25625
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332710
Employees
12
Ownership type
A

3 citations on file for this inspection.

1910.212 A01

Serious Gravity 5 4 instances 2 exposed
Issued
Dec 10, 2024
Penalty
Initial $5,531 · Current $5,000 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks.  a) Machine shop, SN 14351; On or about October 17, 2024 and times prior, employees were using a Swift lathe to repair equipment.  The lathe was not equipped with a chuck guard, exposing employees to struck by hazards from flying chips.  b) Machine shop, located near the bathroom; On or about October 17, 2024 and times prior, employees were using an American lathe to repair equipment.  The lathe was not equipped with a chuck guard, exposing employees to struck by hazards from flying chips.  c) Machine shop, located near the entrance to the shop; On or about October 17, 2024 and times prior, employees were using a Cincinnati drill press to drill holes in parts.  The rotating drill bit was not provided with a guard to prevent employee exposure to the flying chips.  d) Machine shop, located across from the bathroom; On or about October 17, 2024 and times prior, employees were using a Summit drill press to drill holes in parts.  The rotating drill bit was not provided with a guard to prevent employee exposure to the flying chips.
Recent events (2)
  • — I (S) $5000
  • — Z (S) $5531

1910.22 A01

Serious Gravity 1 1 instance 2 exposed
Issued
Dec 10, 2024
Abate by
Jan 7, 2025
Penalty
Initial $2,765 · Current $2,000 Reduced
29 CFR  1910.22(a)(1): The employer failed to provide a clean and sanitary condition for all places of employment, passageways, storerooms, service rooms, and walking-working surfaces.   a) Saw room; On or about October 17, 2024 employees used circuit breaker panels to turn on lights and equipment.  The area around the panels were blocked with parts and pallets exposing employees to tripping hazards.
Recent events (2)
  • — I (S) $2000
  • — Z (S) $2765

1910.303 B02

Other-than-serious 2 instances 2 exposed
Issued
Dec 10, 2024
Penalty
Initial $0 · Current $0
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:  a) Saw room; On or about October 17, 2024 employees use a breaker panel to turn lights on and off.  The panel was not installed per manufacturer's instructions in that the panel door was missing exposing employees to electrical hazards.  b) Saw room; On or about October 17, 2024 employees operating a horizontal band saw while standing or sitting in front of electrical panels.  The panel on one breaker panel was not installed per manufacturer's instructions in that the panel door was open, exposing employees to electrical hazards.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347820375.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.