Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: SWEET ADDITIONS DRESSER LLC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of SWEET ADDITIONS DRESSER LLC in 212 WISCONSIN 35 SOUTH, DRESSER, WI 54009 (NAICS 311999). OSHA activity number 347820516.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Sweet Additions Dresser LLC — free Get an email when a new federal OSHA severe-injury report for Sweet Additions Dresser LLC is published. One employer, no account, unsubscribe in one click.
Site address
212 WISCONSIN 35 SOUTH
City
DRESSER
State
WI
ZIP
54009
Mailing
PO BOX 706, DRESSER, WI 54009
Inspection type
Complaint (B)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Last modified
Data loaded
NAICS code
311999
Employees
40
Ownership type
A

4 citations on file for this inspection.

5(a)(1)

Serious Gravity 5 2 instances 31 exposed
Issued
Mar 11, 2025
Abate by
Jul 25, 2025
Penalty
Initial $7,035 · Current $4,925 Reduced
OSH ACT of 1970 Section 5(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to combustible particulate solids deflagration, explosion, and fire hazards associated with an indoor spray dryer:  (a) Drying Department; On or about October 16, 2024, and dates prior, employees were exposed to combustible particulate solid fire hazards from the operation of the indoor Sterner T-2500-10B-32 co-current bussel style spray dryer, using a 6.5 MMBTU direct-fired main burner to evaporate moisture from food ingredient products.  The indoor spray dryer was operated in a manner that presented combustible particulate solid fire hazards in that fuel, oxygen, and an ignition source were capable of being present at the same time within the system.  The indoor spray dryer lacked means of fire suppression.  (b) Drying Department; On or about October 16, 2024, and dates prior, employees were exposed to combustible particulate solid deflagration and explosion hazards from the operation of the indoor Sterner T-2500-10B-32 co-current bussel style spray dryer, using a 6.5 MMBTU direct-fired main burner to evaporate moisture from food ingredient products.  The indoor spray dryer was operated in a manner that presented combustible particulate solid deflagration and explosion hazards in that fuel, oxygen, suspension, containment, and an ignition source were capable of being present at the same time within the system.  The indoor spray dryer lacked means of explosion protection.
Recent events (4)
  • — C $8276
  • — Z $8276
  • — I (S) $4924.5

1910.147 C04 I

Serious Gravity 5 1 instance 3 exposed
Issued
Mar 11, 2025
Abate by
Apr 29, 2025
Penalty
Initial $5,627 · Current $3,939 Reduced
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:  (a) Throughout the facility; On or about October 14, 2024, and dates prior, energy control procedures were not developed and/or documented for employees performing service and maintenance tasks on production and facility equipment including, but not limited to, the double tube steam vessel, double-o vats, waste/slop silo, hot water tank, syrup tank, bulk material handler, air compressor(s), main boiler, spray dryer, etc.
Recent events (4)
  • — C $6620
  • — Z $6620
  • — I (S) $3938.9

1910.147 C05 II

Serious Gravity 5 1 instance 3 exposed
Issued
Mar 11, 2025
Abate by
Apr 29, 2025
Penalty
Initial $0 · Current $0
29 CFR  1910.147(c)(5)(ii): Lockout devices and tagout devices were not used for lockout and tagout purposes only:   (a) Hydrolysis Department; On or about October 16, 2024, and dates prior, lockout locks and tags were permanently affixed to valve handle covers of a closed steam bypass line located on the double tube steam vessel.  The locks and tags had been in place for approximately two years and were not being used for the purpose of performing lockout/tagout.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.147 C05 II B

Serious Gravity 5 1 instance 3 exposed
Issued
Mar 11, 2025
Abate by
Apr 29, 2025
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(5)(ii)(B): Lockout and tagout devices were not standardized within the facility in at least one of the following criteria: color; shape; or size:  (a) Throughout the facility; On or about October 14, 2024, and dates prior, lockout devices used by employees who performed service and maintenance tasks on production and facility equipment including, but not limited to, the double tube steam vessel, double-o vats, waste/slop silo, hot water tank, syrup tank, bulk material handler, air compressor(s), main boiler, spray dryer, etc., were not standardized in color, shape, or size.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View Sweet Additions Dresser LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347820516.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.