OSHA Inspection: 4M PRECISION INDUSTRIES, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of 4M PRECISION INDUSTRIES, INC. in 4000 TECHNOLOGY PARK BLVD, AUBURN, NY 13021 (NAICS 332999). OSHA activity number 347821373.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch 4M Precision Industries, INC. — free Get an email when a new federal OSHA severe-injury report for 4M Precision Industries, INC. is published. One employer, no account, unsubscribe in one click.
Site address
4000 TECHNOLOGY PARK BLVD
City
AUBURN
State
NY
ZIP
13021
Mailing
4000 TECHNOLOGY PARK BLVD, AUBURN, NY 13021
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332999
Employees
15
Ownership type
A

2 citations on file for this inspection.

1910.147 C04 I

Serious Gravity 1 1 instance 2 exposed
Issued
Feb 21, 2025
Penalty
Initial $2,765 · Current $2,074 Reduced
29 CFR  1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:  a) 4M Precision Industries Incorporated, 4000 Technology Park Boulevard, Auburn,  New York, 13021.   On or about 10/17/2024,  procedures were not utilized for the control of potentially hazardous energies when an employee was engaged in set-up operation's on the E45 Niagara Press.
Recent events (2)
  • — I (S) $2073.75
  • — Z (S) $2765

1910.147 C06 I

Other-than-serious 1 instance 2 exposed
Issued
Feb 21, 2025
Penalty
Initial $0 · Current $0
29 CFR  1910.147(c)(6)(i):The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed:  a) 4M Precision Industries Incorporated, 4000 Technology Park Boulevard, Auburn,  New York, 13021.  On or about 10/17/2024, The employer did not conduct periodic inspections of the energy controls procedures at least annually to ensure that the procedures and the requirements of this standard were being followed.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View 4M Precision Industries, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347821373.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.