Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: SCENIC VIEW ROOFING, LLC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of SCENIC VIEW ROOFING, LLC. in 513 EAST PHILADELPHIA AVENUE, BOYERTOWN, PA 19512 (NAICS 238160). OSHA activity number 347822280.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Scenic View Roofing, LLC. — free Get an email when a new federal OSHA severe-injury report for Scenic View Roofing, LLC. is published. One employer, no account, unsubscribe in one click.
Site address
513 EAST PHILADELPHIA AVENUE
City
BOYERTOWN
State
PA
ZIP
19512
Mailing
248 SNAKE HILL ROAD, BIRD IN HAND, PA 17505
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
3
Ownership type
A

3 citations on file for this inspection.

1926.501 B13

Serious Gravity 10 2 instances 3 exposed
Issued
Nov 12, 2024
Abate by
Dec 2, 2024
Penalty
Initial $6,452 · Current $6,452
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b):   a) 513 East Philadelphia Avenue, Boyertown, PA, Roof - On or about October 17, 2024, an employee replacing a residential 8/12 pitch roof was not utilizing acceptable means or methods of fall protection, exposing the employee to a fall hazard of approximately 24 feet to grade.  b) 513 East Philadelphia Avenue, Boyertown, PA, Roof - On or about October 17, 2024, employees replacing a residential 2/12 pitch roof were not utilizing acceptable means or methods of fall protection, exposing the employees to a fall hazard of approximately 8 feet to grade.  Abatement certification and documentation required within 10 days after abatement date. The certification shall include a statement that abatement is complete, the date and method of abatement, and state that employees and their representatives were informed of this abatement. Abatement documentation shall include documents demonstrating that abatement is complete, such as evidence of the purchase or repair of equipment, photographic or video evidence of abatement or other written records.
Recent events (1)
  • — Z (S) $6452

1926.503 A01

Serious Gravity 5 1 instance 3 exposed
Issued
Nov 12, 2024
Abate by
Dec 2, 2024
Penalty
Initial $0 · Current $0
29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee potentially exposed to fall hazards to enable each employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards:  a) 513 East Philadelphia Avenue, Boyertown, PA, Roof - On or about October 17, 2024, Employees replaced the roof of a multi-level 2/12 pitch and 8/12 pitch residential structure. Employees were not trained in appropriate fall protection methods to avoid hazards associated with elevated work areas.  Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and state employees and their representatives were informed of this abatement.
Recent events (1)
  • — Z (S) $0

1926.1053 B01

Serious Gravity 5 1 instance 3 exposed
Issued
Nov 12, 2024
Abate by
Dec 2, 2024
Penalty
Initial $4,610 · Current $4,610
29 CFR  1926.1053(b)(1):Where (a) portable ladder(s) was/were used for access to an upper level landing surface and the ladder's length did not allow the ladder side rails to extend at least 3 feet (0.9 m) above the upper landing surface being accessed, the ladder was not secured at its top to a rigid support that will not deflect, and/or a grasping device was not provided to assist employees in mounting and dismounting the ladder.    a) 513 East Philadelphia Avenue, Boyertown, PA, Roof - On or about October 17, 2024, employees accessed the roof using extension ladders to replace a shingle roof on a multilevel single-family house. Employees used ladders not extended at least 3 feet above the upper landing surface. In addition, the ladders were not secured to a rigid support, and there was no grasping device. Employees were exposed to fall hazards more than 20 feet.   Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and state employees and their representatives were informed of this abatement.
Recent events (1)
  • — Z (S) $4610

View Scenic View Roofing, LLC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347822280.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.