Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: A. PREMAN ROOFING, INC.

Unprogrammed Other inspection · Safety discipline

On , OSHA opened an unprogrammed Other safety inspection of A. PREMAN ROOFING, INC. in BLDG 6005, MCAS MIRAMAR, SAN DIEGO, CA 92145 (NAICS 238160). OSHA activity number 347824849.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch A. Preman Roofing, INC. — free Get an email when a new federal OSHA severe-injury report for A. Preman Roofing, INC. is published. One employer, no account, unsubscribe in one click.
Site address
BLDG 6005, MCAS MIRAMAR
City
SAN DIEGO
State
CA
ZIP
92145
Mailing
875 34TH STREET, SAN DIEGO, CA 92102
Inspection type
Unprogrammed Other (I)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
4
Ownership type
A

5 citations on file for this inspection.

1926.25 A

Deleted Serious Gravity 5 1 instance 5 exposed
Issued
Nov 22, 2024
Abate by
Dec 5, 2024
Penalty
Initial $10,578 · Current $0 Reduced
29 CFR  1926.25(a): During the course of construction, alteration, or repairs,  debris was not kept cleared from work areas, passageways, and stairs, in and around buildings or other structures.  Bldg. 6005: On or about October 17th, 2024, and at times prior thereto, the employer did not ensure walking-working surfaces were maintained in a safe condition. There was several Guardian Fall Protection Temper Reusable Anchor(s) with protruding nail(s) all over the ground.  Employee(s) were potentially exposed to slip, trip, fall and puncture hazard(s).
Recent events (2)
  • — I (S) $0
  • — Z (S) $10578

1926.150 C01 VI

Deleted Serious Gravity 10 3 instances 5 exposed
Issued
Nov 22, 2024
Abate by
Dec 5, 2024
Penalty
Initial $14,518 · Current $0 Reduced
29 CFR  1926.150(c)(1)(vi): A fire extinguisher, rated not less than 10B, was not provided within 50 feet of wherever more than 5 gallons of flammable or combustible liquids or 5 pounds of flammable gas were being used on the jobsite.  Bldg. 6005: On or about October 17th, 2024, and at times prior thereto, the employer did not ensure a fire extinguisher was provided for employee use. Employee(s) used a 5-gallon gas can to conduct roofing activities. This condition potentially exposed employee(s) to fire hazard(s).
Recent events (2)
  • — I (S) $0
  • — Z (S) $14518

1926.501 B01

Deleted Serious Gravity 5 1 instance 5 exposed
Issued
Nov 22, 2024
Penalty
Initial $8,816 · Current $0 Reduced
29 CFR  1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems.  Bldg. 6005: On or about October 17th, 2024, and at times prior thereto, employee(s) were performing roofing activities on top of a building with an unprotected side or edge which was approximately 22 foot fall or more above a lower level was not protected from falling by the use of guardrail systems. This condition potentially exposed employee(s) to fall hazard(s).
Recent events (2)
  • — I (S) $0
  • — Z (S) $8816

1926.502 D21

Other-than-serious Gravity 10 6 instances 5 exposed
Issued
Nov 22, 2024
Abate by
Dec 5, 2024
Penalty
Initial $14,518 · Current $8,710 Reduced
29 CFR  1926.502(d)(21): Personal fall arrest systems were not inspected prior to each use for wear, damage, and other deterioration, and/or defective components were not removed from service.  Bldg. 6005: On or about October 17th, 2024, and at times prior thereto, the employer did not ensure that employee(s) inspected Personal fall arrest system(s)  prior to each use for wear, damage, and other deterioration, and/or defective components to include fall protection harness/equipment inspections record tags were left blank. This condition potentially exposed employee(s) to an approximately 22 foot fall hazard(s).
Recent events (2)
  • — I (O) $8710
  • — Z (S) $14518

1926.502 I03

Other-than-serious Gravity 10 4 instances 5 exposed
Issued
Nov 22, 2024
Abate by
Dec 5, 2024
Penalty
Initial $14,518 · Current $8,710 Reduced
29 CFR  1926.502(i)(3): All covers were not secured when installed so as to prevent accidental displacement by the wind, equipment, or employees.   Bldg. 6005: On or about October 17th, 2024, and at times prior thereto, the employer did not ensure that four (4) fall-guard(s) for the dome skylight(s) were secured to prevent displacement and injury. This condition potentially exposed employees to approximately 22 foot fall hazard(s).
Recent events (2)
  • — I (O) $8710
  • — Z (S) $14518

View A. Preman Roofing, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347824849.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.