BENSALEM, PA —
OSHA Inspection: GARDIAN HOLDINGS LLC
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of GARDIAN HOLDINGS LLC in 1356 ADAMS ROAD, BENSALEM, PA 19020 (NAICS 314999). OSHA activity number 347827677.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- GARDIAN HOLDINGS LLC
- Site address
- 1356 ADAMS ROAD
- City
- BENSALEM
- State
- PA
- ZIP
- 19020
- Mailing
- PO BOX 624, BENSALEM, PA 19020
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 314999
- Employees
- 39
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.147 C04 I
- Issued
- Feb 25, 2025
- Abate by
- Mar 14, 2025
- Penalty
- Initial $6,703 · Current $4,022 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: a) 1356 Adams Rd. Bensalem, PA - On or about October 15, 2024, the employer's energy control procedure for the Cambridge Coater Line #3 was not utilized for de-energization while operators clean the rollers and are exposed to in-going nip point hazards.
Recent events (2)
- — I (S) $4022
- — Z (S) $6703
1910.147 C07 I
- Issued
- Feb 25, 2025
- Abate by
- Mar 14, 2025
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(7)(i): The employer did not provide adequate training to ensure that the purpose and function of the energy control program was understood by employees: a) 1356 Adams Rd. Bensalem, PA - On or about October 15, 2024, the employer did not train employees on the energy control procedure to be used when cleaning the rollers on Coater #3.
Recent events (2)