Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: AIR TECH PRO, LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of AIR TECH PRO, LLC in 6 GILBERT DRIVE, MERRIMACK, NH 03054 (NAICS 238220). OSHA activity number 347831331.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch AIR Tech PRO, LLC — free Get an email when a new federal OSHA severe-injury report for AIR Tech PRO, LLC is published. One employer, no account, unsubscribe in one click.
Establishment
AIR TECH PRO, LLC
Site address
6 GILBERT DRIVE
City
MERRIMACK
State
NH
ZIP
03054
Mailing
3970 POST ROAD, WARWICK, RI 02886
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238220
Employees
8
Ownership type
A

3 citations on file for this inspection.

1926.501 B01

Serious Gravity 5 1 instance 1 exposed
Issued
Jan 14, 2025
Penalty
Initial $3,457 · Current $2,500 Reduced
29 CFR  1926.501(b)(1):Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems.  Site- An employee working from the roof was not protected from a fall of approximately 45 feet where fall protection was not provided by the employer.
Recent events (2)
  • — I (S) $2500
  • — Z (S) $3457

1926.501 B04 I

Serious Gravity 5 1 instance 1 exposed
Issued
Jan 14, 2025
Penalty
Initial $0 · Current $0
29 CFR  1926.501(b)(4)(i): Each employee on walking/working surfaces was not protected from falling through holes (including skylights), more than six feet (1.8 m) above lower levels, by personal fall arrest systems, covers, or guardrail systems erected around such holes.   Site- An employee working from the roof was not protected from a fall  of approximately 14 feet through a roof opening where the hole was not covered and fall protection was not provided by the employer.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.503 A01

Serious Gravity 5 1 instance 1 exposed
Issued
Jan 14, 2025
Penalty
Initial $3,457 · Current $0 Reduced
29 CFR  1926.503(a)(1): The employer did not provide a training program for each employee potentially exposed to fall hazards to enable each employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards:   Site- An employee exposed to a fall hazard while working from the roof was not provided with fall protection training from the employer.
Recent events (2)
  • — I (S) $0
  • — Z (S) $3457