ELK GROVE VILLAGE, IL —
OSHA Inspection: MAPES & SPROWL STEEL LLC DBA MAPES & SPROWL STEEL, POWERED BY UPG
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of MAPES & SPROWL STEEL LLC DBA MAPES & SPROWL STEEL, POWERED BY UPG in 1100 EAST DEVON AVENUE, ELK GROVE VILLAGE, IL 60007 (NAICS 333519). OSHA activity number 347831810.
Where did this inspection happen?
- Site address
- 1100 EAST DEVON AVENUE
- City
- ELK GROVE VILLAGE
- State
- IL
- ZIP
- 60007
- Mailing
- 1100 EAST DEVON AVENUE, ELK GROVE VILLAGE, IL 60007
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 333519
- Employees
- 50
- Ownership type
- A
Citations
4 citations on file for this inspection.
1910.147 C04 I
- Issued
- Mar 21, 2025
- Abate by
- Apr 16, 2025
- Penalty
- Initial $8,276 · Current $5,793 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: a) Production Department- On or about October 15, 2024, the employer did not develop, document and utilize machine specific procedures for employees when they perform servicing or maintenance activities on machines and equipment in the facility, including the Iris Chicago Slitter, the Shunt Machine, and changing the blade on the horizontal bandsaws. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
- — I (S) $5793.2
- — Z (S) $8276
1910.147 C07 I
- Issued
- Mar 21, 2025
- Abate by
- Apr 16, 2025
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(7)(i): The employer did not provide adequate training to ensure that the purpose and function of the energy control program was understood by employees: a) Production Department- On or about October 15, 2024, the employer did not ensure that employees were trained and understood the purpose and function of the energy control program and utilized the procedure required for the safe application, usage, and removal of energy control devices when employees performed tasks, such as maintenance and servicing of machines, including the Iris Chicago Slitter and changing the blade on the horizontal bandsaws. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.212 A01
- Issued
- Mar 21, 2025
- Abate by
- Apr 16, 2025
- Penalty
- Initial $6,620 · Current $4,634 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding were not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: a) Metal Core Department - On October 16, 2024, the employer did not ensure that employees were adequately protected from hazards created by rotating parts, such as the unused portions of the Amada HA-250 Horizontal Band Saw blade. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
- — I (S) $4634
- — Z (S) $6620
1910.178 L05
- Issued
- Mar 21, 2025
- Abate by
- Apr 16, 2025
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.178(l)(5): The employer did not evaluate the competency of the operator who had previously received training appropriate to the truck and working conditions encountered: a) Facility wide- On or about October 16, 2024, the employer did not evaluate the competency of the forklift operators' previous training and experience to ensure that the vehicle and working conditions were similar prior to operating powered industrial vehicles. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).