NEW BRITAIN, CT —
OSHA Inspection: ACME MONACO CORPORATION
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of ACME MONACO CORPORATION in 75 WINCHELL ROAD, NEW BRITAIN, CT 06052 (NAICS 332613). OSHA activity number 347832917.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ACME MONACO CORPORATION
- Site address
- 75 WINCHELL ROAD
- City
- NEW BRITAIN
- State
- CT
- ZIP
- 06052
- Mailing
- 75 WINCHELL ROAD, NEW BRITAIN, CT 06052
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332613
- Employees
- 110
- Ownership type
- A
Citations
23 citations on file for this inspection.
1910.124 J02 I
- Issued
- Jan 3, 2025
- Abate by
- Feb 21, 2025
- Penalty
- Initial $4,666 · Current $2,333 Reduced
General-duty citation text
29 CFR 1910.124(j)(2)(i): The employer did not ensure airflow was adequate at least quarterly during operation: Commercial Cleaning: On, or about, October 30, 2024, the employer did not conduct quarterly airflow inspections to ensure that ventilation provided over the cleaning tanks was functioning as intended. Nitric acid, a corrosive liquid, was used in the cleaning process.
Recent events (2)
- — I (O) $2333
- — Z (S) $4666
1910.124 J03
- Issued
- Jan 3, 2025
- Abate by
- Feb 21, 2025
- Penalty
- Initial $4,666 · Current $0 Reduced
General-duty citation text
29 CFR 1910.124(j)(3): Periodic inspections of all dipping and coating equipment, including covers, drains, overflow piping, and electrical and fire-extinguishing systems were not conducted, and deficiencies were not promptly corrected: Commercial Cleaning: On, or about, October 30, 2024, the employer did not conduct a thorough inspection of the cleaning equipment including tanks, ventilation, electrical systems, safety equipment and auxiliary equipment on at least an annual basis. Nitric acid, a corrosive liquid, was used in the cleaning process.
Recent events (2)
- — I (O) $0
- — Z (S) $4666
1910.132 D01
- Issued
- Jan 3, 2025
- Abate by
- May 1, 2025
- Penalty
- Initial $4,666 · Current $2,333 Reduced
General-duty citation text
29 CFR 1910.132(d)(1): The employer did not assess the workplace to determine if hazards are present, or are likely to be present, which necessitate the use of personal protective equipment (PPE): Company: On, or about, November 6, 2024, the employer had not conducted a personal protective equipment hazard assessment of tasks in the facility that required the use of protective equipment.
Recent events (2)
- — I (S) $2333
- — Z (S) $4666
1910.133 A01
- Issued
- Jan 3, 2025
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.133(a)(1): Protective eye and face equipment was not required where there was a reasonable probability of injury that could be prevented by such equipment: Company: On, or about, November 6, 2024, employees added water to the battery provided on the Clark forklift. Employees were not provided with adequate eye and face protection when adding water to the battery cells in that the employee only wore safety glasses with side shields.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.178 L01 I
- Issued
- Jan 3, 2025
- Abate by
- Feb 21, 2025
- Penalty
- Initial $4,666 · Current $2,333 Reduced
General-duty citation text
29 CFR 1910.178(l)(1)(i): The employer did not ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l): Company: On, or about, November 6, 2024, the employer had not trained and evaluated four employees who operated forklift trucks.
Recent events (2)
- — I (S) $2333
- — Z (S) $4666
1910.178 L04 III
- Issued
- Jan 3, 2025
- Abate by
- Feb 21, 2025
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.178(l)(4)(iii): An evaluation of each powered industrial truck operator's performance was not being conducted at least once every three years: Company: On, or about, November 6, 2024, the employer had not recertified employees who operate forklift trucks at least every three years.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.212 A01
- Issued
- Jan 3, 2025
- Abate by
- May 1, 2025
- Penalty
- Initial $7,779 · Current $3,890 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by pinch points: Four Slide Department: The following four slide machines were provided with a single jog control located within reach of the point of operation: A. Machine F17: Nilson, gray. B. Machine F12: Nilson, gray. C. Machine F14: Nilson, gray. D. Machine F5, Nilson, gray. E. Machine F9: Nilson, gray. F. Machine F4: Nilson, red. G. Machine F7: Nilson, gray. H. Machine F33: Nilson, orange. I. Machine PF4, Nilson, tan.
Recent events (2)
- — I (S) $3889.5
- — Z (S) $7779
1910.212 A04
- Issued
- Jan 3, 2025
- Abate by
- May 1, 2025
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.212(a)(4): Revolving drum(s), barrel(s), or container(s) were not guarded by enclosure(s) which were interlocked with the drive mechanism so that the barrel(s), drum(s), or container(s) could not revolve unless the enclosure(s) were in place: Tumbling: On, or about, October 22, 2024, a rotary barrel used to tumble parts was not enclosed.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.305 G01 IV A
- Issued
- Jan 3, 2025
- Penalty
- Initial $4,666 · Current $2,333 Reduced
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure: Clean Room: On, or about, October 30, 2024, Machine M32-J was energized through an extension cord.
Recent events (2)
- — I (O) $2333
- — Z (S) $4666
1910.305 G01 IV D
- Issued
- Jan 3, 2025
- Abate by
- May 1, 2025
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(D): Flexible cords and cables were used where attached to building surfaces: On, or about, October 22, 2024, in the following locations, flexible cord was attached to building surfaces using plastic tie wraps: A. Secondary Bench, Kickpress Area: A quad receptacle was energized through a flexible cord that was attached onto overhead conduit and a compressed air line. B. Fourslide Area: A duplex receptacle was energized through flexible cord that was attached to the ceiling an on overhead strain relief device using plastic tie-wraps. C. Fourslide Area, Sample Oven: The gray flexible cord that was used to energize the sample oven was attached to the ceiling.
Recent events (2)
- — I (O) $0
- — Z (S) $0
1910.305 J02 I
- Issued
- Jan 3, 2025
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(j)(2)(i): Receptacle(s) were installed as to require an energized attachment plug as its source of supply: Fourslide Area: On, or about, October 22, 2024, a quad receptacle used to energize light fixtures and a battery charger was energized through a cord a plug connection to a wall mounted receptacle.
Recent events (2)
- — I (O) $0
- — Z (S) $0
1910.334 A02 II
- Issued
- Jan 3, 2025
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.334(a)(2)(ii): There was a defect or evidence of damage that could have exposed an employee to injury and the defective or damaged item was not removed from service: Clean Room: On, or about, October 30, 2024, the extension cord used to energize Machine M32-J was damaged. The outer insulation was pulled from the cord cap fitting, exposing the inner, coated conductors.
Recent events (2)
- — I (O) $0
- — Z (S) $0
1910.332 B01
- Issued
- Jan 3, 2025
- Penalty
- Initial $5,289 · Current $2,645 Reduced
General-duty citation text
29 CFR 1910.332(b)(1): Employees were not trained in and familiar with the safety-related work practices required by 1910.331 through 1910.335 that pertained to their respective job assignments: Company: On, or about, November 6, 2024, maintenance personnel had not been trained regarding what work practices and protective equipment was required to protect them against electric shock, arc flash and arc blast hazards while performing live diagnostic testing and when verifying whether or not electrical equipment was properly de-energized.
Recent events (2)
- — I (S) $2644.5
- — Z (S) $5289
1910.335 A01 I
- Issued
- Jan 3, 2025
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.335(a)(1)(i): Employees working in areas where there were potential electrical hazards were not provided with electrical protective equipment that was appropriate for the specific parts of the body that needed to be protected and for the work being performed: Company: On, or about, November 6, 2024, Personal protective equipment such as, but not limited to, fire resistive clothing, face shields and hard hats were not provided to employees who performed live electrical work, including trouble-shooting, or who verified that electrical equipment was properly de-energized.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.335 A01 II
- Issued
- Jan 3, 2025
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.335(a)(1)(ii): Protective equipment was not maintained in a safe, reliable condition and/or was not periodically inspected or tested: Ref. 29 CFR 1910.137(c)(2)(viii) and Table I-5 Company: On, or about, November 6, 2024, a pair of Salisbury Class 00 voltage rated gloves had not been inspected since 2012.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.1030 C01 IV
- Issued
- Jan 3, 2025
- Abate by
- Feb 21, 2025
- Penalty
- Initial $4,666 · Current $0 Reduced
General-duty citation text
29 CFR 1910.1030(c)(1)(iv): The Exposure Control Plan was not reviewed and updated at least annually: Company: On, or about, November 6, 2024, the employer had not reviewed and updated the Exposure Control Plan in the previous twelve months.
Recent events (2)
- — I (S) $0
- — Z (S) $4666
1910.1030 C02 I
- Issued
- Jan 3, 2025
- Abate by
- Feb 21, 2025
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1030(c)(2)(i): The employer having employees with occupational exposure did not prepare an exposure determination: Company: On, or about, November 6, 2024, the Exposure Control Plan did not include an Exposure Determination to include the tasks associated with employees acting as designated First Aid responders.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1904.29 B03
- Issued
- Jan 3, 2025
- Abate by
- Feb 21, 2025
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1904.29(b)(3): Each recordable injury or illness on the OSHA 300 Log and 301 Incident Report was not recorded within seven (7) calendar days of receiving information that a recordable injury or illness has occurred: Company: On, or about, October 22, 2024, the following injuries/illnesses had not been recorded on the OSHA 300 log, or equivalent, and on an OSHA 301, or equivalent, within seven days of the occurrence: A. July 8, 2024, bilateral carpal tunnel syndrome that resulted in light duty, lost time and medical treatment. B. July 30, 2024, bilateral cubital tunnel syndrome that resulted in medical treatment.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.217 B07 XII
- Issued
- Jan 3, 2025
- Abate by
- Feb 21, 2025
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.217(b)(7)(xii): The clutch/brake control(s) of mechanical power press(es) with part revolution clutches did not incorporate an automatic means to prevent initiation or continued activation of the single stroke or continuous functions unless the press drive is energized and in the forward direction: Press Area: On, or about, October 22, 2024, PP1, a Minster straight sided partial revolution mechanical power press could run in reverse. The press controls allowed the press to make a single stroke while the flywheel ran in the reverse direction.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.217 D09 II
- Issued
- Jan 3, 2025
- Abate by
- May 1, 2025
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.217(d)(9)(ii): Spring loaded turnover bars were not provided for mechanical power press(es) designed to accept such turnover bars: Press Area: On, or about, October 30, 2024, the turnover bar used at the following Minster straight sided partial revolution mechanical power presses was not spring-loaded: A. PP3. B. PP4. C. PP5.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.219 I02
- Issued
- Jan 3, 2025
- Abate by
- Feb 21, 2025
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.219(i)(2): Revolving surfaces of shaft coupling(s) were not covered by a safety sleeve: Medical Coiling: On, or about, October 22, 2024, a cover/guard had not been provided on the shaft coupling provided on Machine #NISW 2 Nito Speed Winder.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.242 B
- Issued
- Jan 3, 2025
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.: Clean Room: On, or about, October 30, 2024, a compressed air nozzle used for cleaning was measured to be 85 p.s.i, dead-ended.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.1200 F06 II
- Issued
- Jan 3, 2025
- Abate by
- Feb 21, 2025
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(f)(6)(ii): Except as provided in 29 CFR 1910.1200(f)(7) and 29 CFR 1910.1200(f)(8), the employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the product identifier and words, pictures, symbols, or combination thereof, which provide at least general information regarding the hazards of the chemicals and which, in conjunction with the other information immediately available to employees under the hazard communication program, would provide employees with the specific information regarding the physical and health hazards of the hazardous chemical: Morton Building, Exterior: On, or about, November 6, 2024, a compressed gas storage tank that contained propane, a Category 1 flammable gas, was not provided with a label/placard to identify the contents and the associated hazard warnings.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Acme Monaco Corporation
View Acme Monaco Corporation's full OSHA safety record →
More inspections in this industry (NAICS 332613)
More inspections in CT
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347832917.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.