DALLAS, TX ·
OSHA Inspection: THE PECAN DELUXE CANDY COMPANY
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of THE PECAN DELUXE CANDY COMPANY in 2570 LONE STAR DR, DALLAS, TX 75212 (NAICS 311352). OSHA activity number 347839789.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- THE PECAN DELUXE CANDY COMPANY
- Site address
- 2570 LONE STAR DR
- City
- DALLAS
- State
- TX
- ZIP
- 75212
- Mailing
- 2570 LONE STAR DR, DALLAS, TX 75212
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 311352
- Employees
- 280
- Ownership type
- Private (A)
Citations
2 citations on file for this inspection.
1910.147 C04 I
- Issued
- Mar 28, 2025
- Abate by
- Apr 23, 2025
- Penalty
- Initial $16,550 · Current $9,930 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented, and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: (a) On or before October 24, 2024, employees were not protected from machinery hazards related to the unexpected energization, startup, or release of stored energy while removing, cleaning, and replacing the spool valve on the bottom of the depositor of the Hinds-Bock twin servo pump filler on line 2 in that the employer did not ensure utilization of specific energy control procedures. (b) On or before October 24, 2024, employees were not protected from machinery hazards related to the unexpected energization, startup, or release of stored energy while removing, cleaning, and replacing the spool valve on the bottom of the depositor of the Hinds-Bock twin servo pump filler on line 3 in that the employer did not ensure utilization of specific energy control procedures.
Recent events (2)
- · I (S) $9930
- · Z (S) $16550
1910.212 A03 II
- Issued
- Mar 28, 2025
- Abate by
- Apr 23, 2025
- Penalty
- Initial $16,550 · Current $9,930 Reduced
General-duty citation text
29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s): (a) On October 18, 2024, employees were not protected from any part of their body being caught in the spout spool at the low end of the depositor of the Hinds-Bock twin servo pump filler on line 2 in that its point of operation was not guarded when unclogging during normal operation. (b) On October 18, 2024, employees were not protected from any part of their body being caught in the spout spool at the low end of the depositor of the Hinds-Bock twin servo pump filler on line 3 in that its point of operation was not guarded when unclogging during normal operation.
Recent events (2)
- · I (S) $9930
- · Z (S) $16550
More inspections at The Pecan Deluxe Candy Company
View The Pecan Deluxe Candy Company's full OSHA safety record →
More inspections in this industry (NAICS 311352)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 347839789.