SPRINGFIELD, IL —
OSHA Inspection: SELVAGGIO ORNAMENTAL & STRUCTURAL STEEL, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of SELVAGGIO ORNAMENTAL & STRUCTURAL STEEL, INC. in 1119 W DORLAN AVENUE, SPRINGFIELD, IL 62702 (NAICS 332312). OSHA activity number 347851271.
Where did this inspection happen?
- Establishment
- SELVAGGIO ORNAMENTAL & STRUCTURAL STEEL, INC.
- Site address
- 1119 W DORLAN AVENUE
- City
- SPRINGFIELD
- State
- IL
- ZIP
- 62702
- Mailing
- 1119 W DORLAN AVENUE, SPRINGFIELD, IL 62702
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332312
- Employees
- 25
- Ownership type
- A
Citations
4 citations on file for this inspection.
1910.147 C04 II B
- Issued
- Abate by
- Penalty
- Initial $3783.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(ii)(B): The energy control procedures did not clearly and specifically outline the steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy: On or about October 30, 2024, an employee was exposed to machine hazards associated with moving parts within the point of operation when performing punch and die set up and preventative maintenance activities on the Peddinghaus 623- C Anglemaster Automated Punch Press hydraulic assemblies. The employer's documented procedure did not outline specific procedural steps for shutting down and isolating the hydraulic and pneumatic energy sources.
Recent events (2)
- — I (O) $0
- — Z (S) $3783
1910.147 C04 II C
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.147(c)(4)(ii)(C): The energy control procedure did not clearly and specifically outline the steps for placement, removal and transfer of lockout devices or tagout devices and the responsibility for them: On or about October 30, 2024, an employee was exposed to machine hazards associated with moving parts within the point of operation when performing punch and die set up and preventative maintenance activities on the Peddinghaus 623- C Anglemaster Automated Punch Press hydraulic assemblies. The employer's documented procedure did not outline steps for placement, removal, and transfer of lockout devices for hydraulic and pneumatic energy sources.
Recent events (2)
- — I (O) $0
- — Z (S) $0
1910.147 C04 II D
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.147(c)(4)(ii)(D): The energy control procedures did not clearly and specifically outline the requirements for testing a machine or equipment to determine and verify the effectiveness of lockout devices, tagout devices, and other energy control: On or about October 30, 2024, an employee was exposed to machine hazards associated with moving parts within the point of operation when performing punch and die set up and preventative maintenance activities on the Peddinghaus 623- C Anglemaster Automated Punch Press hydraulic assemblies. The employer's documented procedure did not outline steps for testing of machine to verify effectiveness of lockout devices for hydraulic and pneumatic energy sources.
Recent events (2)
- — I (O) $0
- — Z (S) $0
1910.147 D
- Issued
- Abate by
- Penalty
- Initial $3783.00 · Current $3783.00
General-duty citation text
29 CFR 1910.147(d): The established procedure for the application of energy control (the lockout or tagout procedures) did not cover the actions listed in and was not done in sequence as required by 29 CFR 1910.147(d)(1)-(6): On or about October 30, 2024, an employee was exposed to machine hazards associated with moving parts within the point of operation when performing punch and die set up and preventative maintenance activities on the Peddinghaus 623- C Anglemaster Automated Punch Press hydraulic assemblies. The employer failed to implement energy control application steps as the energy isolation device was not affixed with a lockout device [per the 1910.147(d)(4) requirement]. As a result, the remaining applicable energy control elements, involving dissipation of residual energy [(d)(5)(i)], and verification of isolation [(d)(6)], were not implemented to protect employees from machine servicing hazards.
Recent events (2)
- — I (S) $3783
- — Z (S) $3783
More inspections in this industry (NAICS 332312)
WYOMING, MI—2026-07-16
R&M FABRICATION LLC
TRUSSVILLE, AL—2026-07-16
ALL SOUTH STEELWORX, LLC
NORTH BRANCH, MN—2026-07-15
111603 - BROWN HAWK LLC DBA NORTHERN LIGHTS STEEL FAB
VAN BUREN, AR—2026-07-14
MILLAR PARTNERS, LLC
CLANTON, AL—2026-07-14
C & S CANOPY, INC.
More inspections in IL
DEERFIELD, IL—2026-07-16
JOHN BURNS CONSTRUCTION COMPANY, LLC
BANNOCKBURN, IL—2026-07-16
BUILDER SERVICES GROUP, INC. DBA CJ INSULATION
BANNOCKBURN, IL—2026-07-16
ROOFING H.P. LLC
HIGHLAND PARK, IL—2026-07-16
UNITED PLUMBING AND DRAIN, INC.
FRANKLIN PARK, IL—2026-07-16
B & M PLASTIC INC.
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347851271.