DEPOSIT, NY —
OSHA Inspection: LIGNETICS OF NEW YORK, LLC
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of LIGNETICS OF NEW YORK, LLC in 1580 AIRPORT ROAD, DEPOSIT, NY 13754 (NAICS 321999). OSHA activity number 347862286.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- LIGNETICS OF NEW YORK, LLC
- Site address
- 1580 AIRPORT ROAD
- City
- DEPOSIT
- State
- NY
- ZIP
- 13754
- Mailing
- 1580 AIRPORT ROAD, DEPOSIT, NY 13754
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 321999
- Employees
- 24
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.28 B03 IV
- Issued
- Apr 11, 2025
- Penalty
- Initial $10,050 · Current $6,300 Reduced
General-duty citation text
29 CFR 1910.28(b)(3)(iv):29 CFR 1910.28(b)(3)(iv): The employer did not provide that each employee be protected from falling into a ladderway floor hole or ladderway platform hole by a guardrail system and toeboards erected on all exposed sides, except at the entrance to the hole, where a self-closing gate or an offset must be used. a) Lignetics of New York, 1580 Airport Road, Deposit, 14551, Second Floor Metering Bin Mezzanine. On or about 10/29/2024, employees were exposed to a fall hazard of approximately 10 feet when the fixed ladderway used to access the second floor mezzanine was without protection from falling onto the lower level. The ladderway did not have a self-closing gate and/or was not offset.
Recent events (2)
- — I (S) $6300
- — Z (S) $10050
1910.134 C02 I
- Issued
- Apr 11, 2025
- Penalty
- Initial $6,029 · Current $0 Reduced
General-duty citation text
29 CFR 1910.134(c)(2)(i):Respirator users were not provided with the information contained in Appendix D to 29 CFR 1910.134 when the employer determined that any voluntary respirator use was permissible: a) Lignetics of New York, 1580 Airport Road, Deposit, 14551. On or about 10/29/2024, the employer did not provide employees with the information contained in Appendix D of the Respiratory Protection Standard ("Information for Employees Using Respirators When Not Required Under the Standard"), when the employer permitted employees to use a 3M Model 8511, N95 Filtering Face-Piece Respirator.
Recent events (2)
- — I (O) $0
- — Z (S) $6029
More inspections in this industry (NAICS 321999)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347862286.