Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: LIGNETICS OF NEW YORK, LLC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of LIGNETICS OF NEW YORK, LLC in 1580 AIRPORT ROAD, DEPOSIT, NY 13754 (NAICS 321999). OSHA activity number 347862286.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Lignetics of NEW York, LLC — free Get an email when a new federal OSHA severe-injury report for Lignetics of NEW York, LLC is published. One employer, no account, unsubscribe in one click.
Site address
1580 AIRPORT ROAD
City
DEPOSIT
State
NY
ZIP
13754
Mailing
1580 AIRPORT ROAD, DEPOSIT, NY 13754
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
321999
Employees
24
Ownership type
A

2 citations on file for this inspection.

1910.28 B03 IV

Serious Gravity 5 1 instance 2 exposed
Issued
Apr 11, 2025
Penalty
Initial $10,050 · Current $6,300 Reduced
29 CFR  1910.28(b)(3)(iv):29 CFR 1910.28(b)(3)(iv):  The employer did not provide that each employee be protected from falling into a ladderway floor hole or ladderway platform hole by a guardrail system and toeboards erected on all exposed sides, except at the entrance to the hole, where a self-closing gate or an offset must be used.  a) Lignetics of New York, 1580 Airport Road, Deposit, 14551, Second Floor Metering Bin Mezzanine.   On or about 10/29/2024, employees were exposed to a fall hazard of approximately 10 feet when the  fixed ladderway used to access the second floor mezzanine was without protection from falling onto the lower level.   The ladderway did not have a self-closing gate and/or was not offset.
Recent events (2)
  • — I (S) $6300
  • — Z (S) $10050

1910.134 C02 I

Other-than-serious Gravity 1 1 instance 2 exposed
Issued
Apr 11, 2025
Penalty
Initial $6,029 · Current $0 Reduced
29 CFR  1910.134(c)(2)(i):Respirator users were not provided with the information contained in Appendix D to 29 CFR 1910.134 when the employer determined that any voluntary respirator use was permissible:  a) Lignetics of New York, 1580 Airport Road, Deposit, 14551.   On or about 10/29/2024, the employer did not provide employees with the information contained in Appendix D of the Respiratory Protection Standard ("Information for Employees Using Respirators When Not Required Under the Standard"), when the employer permitted employees to use a 3M Model 8511, N95 Filtering Face-Piece Respirator.
Recent events (2)
  • — I (O) $0
  • — Z (S) $6029

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347862286.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.