Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,645Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: MARIANO'S GARAGE DOORS & CONSTRUCTION INCORPORATED

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of MARIANO'S GARAGE DOORS & CONSTRUCTION INCORPORATED in 7000 FOSTER AVENUE, CHICAGO, IL 60644 (NAICS 238160). OSHA activity number 347866691.

Watch Mariano'S Garage Doors & Construction Incorporated — free Get an email when a new federal OSHA severe-injury report for Mariano'S Garage Doors & Construction Incorporated is published. One employer, no account, unsubscribe in one click.
Site address
7000 FOSTER AVENUE
City
CHICAGO
State
IL
ZIP
60644
Mailing
729 N LARAMIE 2ND FLOOR, CHICAGO, IL 60644
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Last modified
Data loaded
NAICS code
238160
Employees
4
Ownership type
A

3 citations on file for this inspection.

1926.102 A01

Serious Gravity 1 1 instance 3 exposed
Issued
Penalty
Initial $2074.00 · Current $2074.00
29 CFR  1926.102(a)(1):The employer did not ensure that each affected employee use appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors or potentially injurious light radiation.  a) On November 7, 2024, at the above-mentioned address, employees were exposed to eye injury while operating pneumatic nail guns without the benefit of eye protection.   No abatement certification or documentation is required for this item.
Recent events (1)
  • — Z (S) $2074

1926.501 B13

Serious Gravity 10 1 instance 3 exposed
Issued
Penalty
Initial $4839.00 · Current $4839.00
29 CFR  1926.501(b)(13):Each employee engaged in residential construction activities 6 feet or more above lower levels was not protected by guardrail systems, safety net systems, or personal fall arrest systems, nor were the employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501(b):   a)On November 7, 2024, at the above-mentioned address, employees were exposed to fall hazards of approximately 11.6 feet ground to eave while performing residential roofing work without the use of fall  protection.  No abatement certification or documentation is required for this item.
Recent events (1)
  • — Z (S) $4839

1926.1053 B13

Serious Gravity 5 1 instance 3 exposed
Issued
Penalty
Initial $3457.00 · Current $3457.00
29 CFR  1926.1053(b)(13):Portable ladders were used for access to an upper landing surface and the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder was used to gain access:   a) On or about November 7, 2024, an extension ladder used by employees to gain access to the working surface did not have its side rails extended 3 feet above the upper landing being accessed.  No abatement certification or documentation is required for this item.
Recent events (1)
  • — Z (S) $3457

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347866691.